Metraipolis › archive › dc_bf349b213023
The Signal in the Noise: An Auditable Reliability Layer for Biomedical Text Classification — arXiv:2608.28595
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2608.28595
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-17T07:41:34.649Z
- SHA-256 of the archived text
2a7aee7f26f95e6894460690678410da169dd4a360947cd62d527488beada41b- Stable URL of this page
https://metraipolis.com/documento/dc_bf349b213023
How to cite
The Signal in the Noise: An Auditable Reliability Layer for Biomedical Text Classification — arXiv:2608.28595 — arXiv (en), https://arxiv.org/abs/2608.28595 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_bf349b213023 (Metraipolis archive dc_bf349b213023, sha256 2a7aee7f26f95e6894460690678410da169dd4a360947cd62d527488beada41b)
BibTeX
@misc{dcbf349b213023,
title = {The Signal in the Noise: An Auditable Reliability Layer for Biomedical Text Classification — arXiv:2608.28595},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2608.28595},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_bf349b213023; sha256 2a7aee7f26f95e6894460690678410da169dd4a360947cd62d527488beada41b},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.28595. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Biomedical NLP pipelines routinely presuppose clean input text, yet large-scale corpora assembled through automated PDF parsing harbour pervasive OCR-like artifacts, token splits and merges, hyphenation remnants, and character-level corruption, that systematically erode lexical evidence and degrade downstream classifiers. We introduce a conservative, fully auditable spell-correction reliability layer conceived as a safety-oriented preprocessing module rather than a maximal-accuracy corrector: under conditions of uncertainty, the system abstains from editing, in accordance with a medical do-no-harm philosophy. The deterministic architecture couples bounded edit-distance candidate generation with corpus-derived n-gram scoring and a suite of biomedical safety gates that protect domain-critical terminology. We evaluate the layer both intrinsically, on a manually curated benchmark of 2,104 token-level cases, and extrinsically, on a tri-class CORD-19 topic classifier (Prevention, Treatment, Epidemiology) spanning 10,000 examples under a principled four-run protocol (Clean, Noisy, Restored, Safety). Intrinsically, the layer attains 94.61% error-fix recall on synthetic errors with zero harmful edits on negative controls. Downstream, it recovers approximately 80.45% of the noise-induced macro-F1 degradation, elevating macro-F1 from 0.7654 (Noisy) to 0.7717 (Restored) while preserving near-clean performance (Safety: 0.7721). A supplementary case study on 103 real-world OCR-extracted abstracts classified with BioBERT confirms that transformer encoders appeared relatively robust to mild noise, motivating a future grey-box architecture that integrates bounded neural signals and UMLS lexicons without compromising auditability. The system is fully deterministic, artifact-driven, and designed with deployment and auditability in mind. Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-01 in cs.AI). Categorie arXiv: Artificial Intelligence (cs.AI) ; Computation and Language (cs.CL); Machine Learning (cs.LG). Pagina del lavoro: https://arxiv.org/abs/2608.28595 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-17T07:28:26.441Z dalla pagina https://arxiv.org/catchup/cs.AI/2026-09-01?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).