Metraipolis › archive › dc_bf095f48ae27
A Portable Multichannel Kilohertz Current Stimulator for Selective Peripheral Transcutaneous Stimulation — arXiv:2609.23075
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.23075
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-10T00:58:03.907Z
- SHA-256 of the archived text
7f2e6a8853c59a0d18da5be28e5cc2f2ff9801972bd043996f783ca2b22a81af- Stable URL of this page
https://metraipolis.com/documento/dc_bf095f48ae27
How to cite
A Portable Multichannel Kilohertz Current Stimulator for Selective Peripheral Transcutaneous Stimulation — arXiv:2609.23075 — arXiv (en), https://arxiv.org/abs/2609.23075 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_bf095f48ae27 (Metraipolis archive dc_bf095f48ae27, sha256 7f2e6a8853c59a0d18da5be28e5cc2f2ff9801972bd043996f783ca2b22a81af)
BibTeX
@misc{dcbf095f48ae27,
title = {A Portable Multichannel Kilohertz Current Stimulator for Selective Peripheral Transcutaneous Stimulation — arXiv:2609.23075},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.23075},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_bf095f48ae27; sha256 7f2e6a8853c59a0d18da5be28e5cc2f2ff9801972bd043996f783ca2b22a81af},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.23075. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
We present SineStim, a portable, 12-channel current stimulator for transcutaneous spinal cord stimulation and peripheral electrical stimulation at kilohertz frequencies. Each channel delivers independent, current-controlled sinusoidal waveforms with amplitudes from 0 to 50 mA (0.1 mA resolution) and frequencies from 0 to 50 kHz (0.1 Hz resolution), with burst modulation modes supported. A custom output stage with a high compliance voltage of $\pm$ 120 V was designed and developed, with galvanically isolated channels and independently programmable stimulation parameters for each channel. The stimulator performance was tested on both passive loads and human subjects. Benchtop characterisation on resistive and resistive-capacitive loads demonstrated a total harmonic distortion between 1 - 8 % across typical operating conditions. Multichannel functionality was demonstrated in two-channel human forearm stimulation experiments. Burst-modulated waveforms with differing channel amplitudes modulated inter-finger force ratios, and channels with small frequency offsets elicited temporal interference force patterns at the beat frequency. Smoothly enveloped bursts of kilohertz sinusoidal waveforms produced negligible stimulation artifacts at steady state in concurrent surface electromyography (sEMG) recordings at motor threshold, in contrast to conventional biphasic square wave stimulation. SineStim delivers precise, isolated, multichannel kilohertz stimulation through a portable device, with performance demonstrated on both benchtop loads and human participants. By combining multichannel spatial control with minimal-artifact sEMG compatibility, SineStim enables future precision non-invasive neural stimulation paradigms based on multichannel optimisation and real-time closed-loop control capabilities not available via existing single-channel stimulators. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-22 in eess.SP). Categorie arXiv: Signal Processing (eess.SP). Pagina del lavoro: https://arxiv.org/abs/2609.23075 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-09T23:57:50.937Z dalla pagina https://arxiv.org/catchup/eess.SP/2026-09-22?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).