Metraipolis › archive › dc_bec7cbc25648
Learning Where and What to Lift for Bi-planar X-ray-to-CT Reconstruction — arXiv:2608.17255
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2608.17255
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-18T14:29:19.199Z
- SHA-256 of the archived text
cd7dfd661ae9d4dddfe10a2e78dfddd5fa239b6a8c21ab6efcc8adfde422830e- Stable URL of this page
https://metraipolis.com/documento/dc_bec7cbc25648
How to cite
Learning Where and What to Lift for Bi-planar X-ray-to-CT Reconstruction — arXiv:2608.17255 — arXiv (en), https://arxiv.org/abs/2608.17255 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_bec7cbc25648 (Metraipolis archive dc_bec7cbc25648, sha256 cd7dfd661ae9d4dddfe10a2e78dfddd5fa239b6a8c21ab6efcc8adfde422830e)
BibTeX
@misc{dcbec7cbc25648,
title = {Learning Where and What to Lift for Bi-planar X-ray-to-CT Reconstruction — arXiv:2608.17255},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2608.17255},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_bec7cbc25648; sha256 cd7dfd661ae9d4dddfe10a2e78dfddd5fa239b6a8c21ab6efcc8adfde422830e},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.17255. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
X-ray imaging can be approximately modeled as the projection of an underlying volumetric attenuation field, with each measurement recording the accumulated attenuation along a corresponding ray path. Reconstructing a CT volume from only a few X-ray views is therefore severely ill-posed, as the projections collapse depth information and leave 3D locations of anatomical regions and their corresponding intensity distributions highly entangled and ambiguous. We observe that once the spatial organization of anatomical regions is established, estimating their CT intensities becomes substantially more tractable. Motivated by this, we propose LiftXR, an interleaved, geometry-guided framework that explicitly incorporates spatial layout recovery into CT reconstruction. Specifically, a layout lifter first generates a 3D anatomical layout from bi-planar X-rays, providing spatial guidance for an intensity renderer to reconstruct a CT volume. An anatomical parser then performs volumetric perception on the reconstruction, exploiting its spatially resolved boundary and intensity cues to recover a refined anatomical layout. This transition from projection-conditioned layout generation to reconstruction-conditioned anatomical perception allows the parsed layout to provide feedback for region-specific intensity calibration. Extensive experiments on two public datasets demonstrate that LiftXR consistently outperforms recent X-ray-to-CT reconstruction methods, establishing a new state of the art. Moreover, the reconstructed CT achieves superior performance in external downstream segmentation, indicating improved anatomical fidelity. Code will be released. Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-08-19 in cs.AI). Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV) ; Artificial Intelligence (cs.AI). Pagina del lavoro: https://arxiv.org/abs/2608.17255 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-18T14:27:54.403Z dalla pagina https://arxiv.org/catchup/cs.AI/2026-08-19?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).