Metraipolis › archive › dc_be954a2d65dc

Interpretable AI plus Handheld, Portable Retinal Photographs: A Low-Cost Glaucoma Screening Solution for West Africa — arXiv:2609.25697

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.25697
License (as archived)
CC0-1.0
Archived
2026-10-08T13:46:34.233Z
SHA-256 of the archived text
e391bf7450225fe6ce1cf037034a580e6bc99d54f036504b3a634de4e072c67d
Stable URL of this page
https://metraipolis.com/documento/dc_be954a2d65dc

How to cite

Interpretable AI plus Handheld, Portable Retinal Photographs: A Low-Cost Glaucoma Screening Solution for West Africa — arXiv:2609.25697 — arXiv (en), https://arxiv.org/abs/2609.25697 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_be954a2d65dc (Metraipolis archive dc_be954a2d65dc, sha256 e391bf7450225fe6ce1cf037034a580e6bc99d54f036504b3a634de4e072c67d)
BibTeX
@misc{dcbe954a2d65dc,
  title = {Interpretable AI plus Handheld, Portable Retinal Photographs: A Low-Cost Glaucoma Screening Solution for West Africa — arXiv:2609.25697},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.25697},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_be954a2d65dc; sha256 e391bf7450225fe6ce1cf037034a580e6bc99d54f036504b3a634de4e072c67d},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.25697. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Purpose: To develop and evaluate an interpretable artificial intelligence (AI) framework for glaucoma screening from low-cost portable, handheld retinal fundus photographs in a West African population and to compare its performance with clinical tabletop fundus imaging. Methods: We used data from a community-based study of 681 participants (1,362 eyes) in Nigeria, comprising 414 glaucoma, 478 glaucoma suspect, and 470 non-glaucoma eyes. Fundus photographs were acquired using the low-cost handheld, portable Volk Viva retinal camera and the Canon CR-2-AF tabletop camera. We fine-tuned component models separately to each device to perform vessel segmentation, cup and disc boundary segmentation, and feature extraction to detect optic nerve head features. A final classification model combined these components to classify scans as glaucoma, glaucoma suspect or non-glaucoma. Feature-weight analysis and Gradient-weighted Class Activation Mapping were used for interpretation. Results: The models performed well on both Volk Viva and Canon CR-2-AF images: Vessel segmentation: 0.98 Dice Coefficient (DC) (Volk) and 0.94 DC (Canon); Cup and disc segmentation: 0.95 DC (Volk) and 0.96 DC (Canon); Optic nerve head feature detection: area under the receiver operating characteristic curve (AUCs) of 0.83$\pm$0.03 (Volk) and 0.87$\pm$0.04 (Canon); Classification model: AUCs of 0.85$\pm$0.01 (Volk) and 0.93$\pm$0.01 (Canon). Reports for each image, present model decision confidence scores and decision-rationale visualizations to support clinical interpretation. Conclusions: Volk Viva results were reasonably comparable to Canon CR-2-AF in the component models and not far behind in classification. This shows that interpretable AI combined with low-cost, portable imaging may enhance community-level glaucoma screening, especially in settings with limited specialist access and resources.

Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-23 in cs.AI).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV) ; Artificial Intelligence (cs.AI).
Pagina del lavoro: https://arxiv.org/abs/2609.25697 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-08T13:18:38.252Z dalla pagina https://arxiv.org/catchup/cs.AI/2026-09-23?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).