Metraipolis › archive › dc_bcd834d09673
Sparse-View 3D Coronary Reconstruction from Vessel Segmentations Using a Diffusion Prior — arXiv:2611.04604
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2611.04604
- License (as archived)
- CC0-1.0
- Archived
- 2026-11-04T12:57:35.934Z
- SHA-256 of the archived text
d8b7a7a0dbc7fe1718af2707f18c71818368924ed675b50e9c94417520173568- Stable URL of this page
https://metraipolis.com/documento/dc_bcd834d09673
How to cite
Sparse-View 3D Coronary Reconstruction from Vessel Segmentations Using a Diffusion Prior — arXiv:2611.04604 — arXiv (en), https://arxiv.org/abs/2611.04604 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_bcd834d09673 (Metraipolis archive dc_bcd834d09673, sha256 d8b7a7a0dbc7fe1718af2707f18c71818368924ed675b50e9c94417520173568)
BibTeX
@misc{dcbcd834d09673,
title = {Sparse-View 3D Coronary Reconstruction from Vessel Segmentations Using a Diffusion Prior — arXiv:2611.04604},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2611.04604},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_bcd834d09673; sha256 d8b7a7a0dbc7fe1718af2707f18c71818368924ed675b50e9c94417520173568},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.04604. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Reconstructing three-dimensional (3D) coronary anatomy from sparse angiographic views could support percutaneous coronary intervention, but limited angular coverage and imperfect vessel segmentations introduce substantial geometric ambiguity. We propose a vessel-specific reconstruction framework combining a learned 3D diffusion prior, visual-hull initialization, and projection-based data consistency. The unconditional diffusion model is trained on coronary vessel masks without paired 2D--3D data and reused across different view counts without retraining. During inference, a scaled visual hull initializes reconstruction, while projection-based updates constrain diffusion refinement using patient-specific vessel observations. We evaluated the framework on simulated angiograms derived from ImageCAS computed tomography angiography volumes using two, four, and eight views at two contrast levels. Across 50 evaluation coronary-tree cases, the proposed method achieved higher mean Dice and clDice than visual hull, deep image prior (DIP), and hash-grid implicit neural representation (INR) at all view counts under reduced contrast. With eight views, improvements over DIP, the best-performing baseline at lower contrast, were approximately 0.13 in Dice and 0.22 in clDice. At higher contrast, performance remained competitive with hash-grid INR, the best-performing eight-view baseline. The preferred diffusion starting timestep depended on observation quality and view count, with excessive refinement reducing accuracy at higher contrast. Projection guidance improved both metrics across all conditions. Averaging stochastic reconstructions further improved accuracy, while sample disagreement localized errors with average-precision gains of 0.14--0.21 over error prevalence. These findings support diffusion-prior reconstruction from sparse vessel observations, although clinical validation remains necessary. Tema degli esploratori: statistica e scienza dei dati (elenco arXiv cs.CV, nuovi lavori del giorno). Categorie arXiv: Image and Video Processing (eess.IV) ; Computer Vision and Pattern Recognition (cs.CV). Pagina del lavoro: https://arxiv.org/abs/2611.04604 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-11-04T12:33:47.252Z dalla pagina https://arxiv.org/list/cs.CV/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).