Metraipolis › archive › dc_bc8e9528c09d

Artifact Annotations Partially Substitute for Per-User Calibration: SAFE-EDA and a Normalization-Controlled Evaluation of Wrist-EDA Affect Recognition — arXiv:2610.01692

Source
arXiv (en)
Original
https://arxiv.org/abs/2610.01692
License (as archived)
CC0-1.0
Archived
2026-10-07T12:38:17.193Z
SHA-256 of the archived text
fa3a06cf3f3f2285e0916f140b3b6126da726ccf95bc30f3a8a0f98b09529870
Stable URL of this page
https://metraipolis.com/documento/dc_bc8e9528c09d

How to cite

Artifact Annotations Partially Substitute for Per-User Calibration: SAFE-EDA and a Normalization-Controlled Evaluation of Wrist-EDA Affect Recognition — arXiv:2610.01692 — arXiv (en), https://arxiv.org/abs/2610.01692 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_bc8e9528c09d (Metraipolis archive dc_bc8e9528c09d, sha256 fa3a06cf3f3f2285e0916f140b3b6126da726ccf95bc30f3a8a0f98b09529870)
BibTeX
@misc{dcbc8e9528c09d,
  title = {Artifact Annotations Partially Substitute for Per-User Calibration: SAFE-EDA and a Normalization-Controlled Evaluation of Wrist-EDA Affect Recognition — arXiv:2610.01692},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2610.01692},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_bc8e9528c09d; sha256 fa3a06cf3f3f2285e0916f140b3b6126da726ccf95bc30f3a8a0f98b09529870},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.01692. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Wrist electrodermal activity (EDA) differs in amplitude from one person to the next, so affect-recognition models normalize their input before classification. Studies that test such models on held-out subjects seldom report where the normalization statistics come from, yet statistics computed from the held-out subject's own recording give the model information that a device does not have when it is first worn. We asked how this choice alters the measured benefit of pretraining. A compact convolutional network, SAFE-EDA, was pretrained on expert artifact annotations from 43 subjects and compared with the same network trained from scratch on the Wearable Stress and Affect Detection (WESAD) dataset (15 subjects, leave-one-subject-out), with two normalization sources crossed with four window hops. When the statistics came only from training subjects, pretraining raised macro-F1 by 0.078 to 0.227; when they came from the held-out user's full recording, the gain fell to between 0.020 and 0.050 and was no longer significant. Artifact supervision was far more useful than self-supervised pretraining on the same recordings (0.078 versus 0.008). Across 13 configurations in two datasets, the pretrained network was better in 12, but on the second dataset (26 subjects) per-user normalization increased the gain instead of reducing it, so the interaction depends on the data. Only five of 50 published WESAD studies state which data were used for normalization. Reporting this choice is necessary to separate first-use performance from performance after calibration.

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-10-02 in eess.SP).
Categorie arXiv: Machine Learning (cs.LG) ; Signal Processing (eess.SP).
Pagina del lavoro: https://arxiv.org/abs/2610.01692 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-07T12:10:56.241Z dalla pagina https://arxiv.org/catchup/eess.SP/2026-10-02?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).