Metraipolis › archive › dc_bc28169d864d

Geometry-anchored PET-aware multimodal pseudo-CT synthesis for whole-body attenuation correction: the BIC-MAC Challenge — arXiv:2609.27848

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.27848
License (as archived)
CC0-1.0
Archived
2026-10-08T12:35:06.139Z
SHA-256 of the archived text
3eb844fc84ff85aad02e903990f47a6f70bb5dcbcb14d4a204bad10a84f14cef
Stable URL of this page
https://metraipolis.com/documento/dc_bc28169d864d

How to cite

Geometry-anchored PET-aware multimodal pseudo-CT synthesis for whole-body attenuation correction: the BIC-MAC Challenge — arXiv:2609.27848 — arXiv (en), https://arxiv.org/abs/2609.27848 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_bc28169d864d (Metraipolis archive dc_bc28169d864d, sha256 3eb844fc84ff85aad02e903990f47a6f70bb5dcbcb14d4a204bad10a84f14cef)
BibTeX
@misc{dcbc28169d864d,
  title = {Geometry-anchored PET-aware multimodal pseudo-CT synthesis for whole-body attenuation correction: the BIC-MAC Challenge — arXiv:2609.27848},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.27848},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_bc28169d864d; sha256 3eb844fc84ff85aad02e903990f47a6f70bb5dcbcb14d4a204bad10a84f14cef},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.27848. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

The BIC-MAC challenge targets whole-body pseudo-CT synthesis from NAC-PET, Dixon MRI, and a 2D topogram for CT-less PET attenuation correction. We propose GeoPACT, a geometry-anchored multimodal framework that uses NAC-PET as the spatial reference and incorporates topogram and MRI features through gated residual fusion. Absolute coordinates and whole-body conditioning support anatomically consistent patch-based prediction. Training combines attenuation-map supervision with a differentiable PET-response surrogate to reduce errors relevant to downstream PET reconstruction. Full-resolution pseudo-CT volumes are generated using sliding-window inference without requiring CT or PET labels at test time.

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-24 in cs.CV).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV).
Pagina del lavoro: https://arxiv.org/abs/2609.27848 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-08T12:12:35.741Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-09-24?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).