Metraipolis › archive › dc_bb4a8cd57b49

Multi-Stage NeRF for Efficient 3D Coronary Artery Reconstruction from Two Narrow-Angle Angiographic Projections — arXiv:2609.15550

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.15550
License (as archived)
CC0-1.0
Archived
2026-10-16T01:53:45.952Z
SHA-256 of the archived text
7149e0c01008e157a455bca0968605ebd8ea982eef26995c1ce7bf5828a89194
Stable URL of this page
https://metraipolis.com/documento/dc_bb4a8cd57b49

How to cite

Multi-Stage NeRF for Efficient 3D Coronary Artery Reconstruction from Two Narrow-Angle Angiographic Projections — arXiv:2609.15550 — arXiv (en), https://arxiv.org/abs/2609.15550 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_bb4a8cd57b49 (Metraipolis archive dc_bb4a8cd57b49, sha256 7149e0c01008e157a455bca0968605ebd8ea982eef26995c1ce7bf5828a89194)
BibTeX
@misc{dcbb4a8cd57b49,
  title = {Multi-Stage NeRF for Efficient 3D Coronary Artery Reconstruction from Two Narrow-Angle Angiographic Projections — arXiv:2609.15550},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.15550},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_bb4a8cd57b49; sha256 7149e0c01008e157a455bca0968605ebd8ea982eef26995c1ce7bf5828a89194},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.15550. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

X-ray coronary angiography is the clinical gold standard for coronary artery disease during real-time cardiac interventions, but provides only 2D projections of inherently 3D vessels. Existing learning-based 2D-to-3D reconstruction methods typically require wide angular coverage or multiple views, assumptions that are rarely satisfied in routine practice where only two projections with narrow angular separation are available. To address these challenges, we propose NeCA++, a multi-stage self-supervised neural radiance field (NeRF) framework tailored to clinically realistic acquisition constraints. The framework decomposes reconstruction into two stages that progressively refine spatial support and representation capacity. In the first stage, a coarse 3D representation of the vasculature is reconstructed, restricting the subsequent optimisation to regions with a higher likelihood of vessel presence, termed an active region. Afterward reconstruction is restricted to this region while higher-resolution representations are progressively activated to recover fine vascular details. This multi-stage strategy focuses learning on anatomically plausible regions, mitigates gradient dilution under extreme sparsity, and stabilises global topology before recovering fine vascular branches. Furthermore, two vessel-specific regularisations are introduced: a ray-aligned constraint to reduce projection-induced ambiguity, and a bimodal density penalty to enable early vessel-background separation. Extensive experiments across three datasets (ImageCAS, ASOCA, and Synthetic RCA) and four angular configurations demonstrate consistent superiority over state-of-the-art baselines, particularly under clinically realistic narrow-angle settings, while achieving reconstruction within 58 seconds per case.

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-15 in cs.CV).
Categorie arXiv: Computational Geometry (cs.CG) ; Computer Vision and Pattern Recognition (cs.CV).
Pagina del lavoro: https://arxiv.org/abs/2609.15550 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-16T01:25:23.744Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-09-15?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).