Metraipolis › archive › dc_b85a03ab7fe3

SPARC: Slice-to-volume Pipeline for Automated Reconstruction of gated 3D+time fetal Cardiac MRI — arXiv:2608.18616

Source
arXiv (en)
Original
https://arxiv.org/abs/2608.18616
License (as archived)
CC0-1.0
Archived
2026-10-18T14:06:20.052Z
SHA-256 of the archived text
cd22ae03375fe22da48800fbb02027244a064e6f2fb5651fe09163357080d875
Stable URL of this page
https://metraipolis.com/documento/dc_b85a03ab7fe3

How to cite

SPARC: Slice-to-volume Pipeline for Automated Reconstruction of gated 3D+time fetal Cardiac MRI — arXiv:2608.18616 — arXiv (en), https://arxiv.org/abs/2608.18616 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_b85a03ab7fe3 (Metraipolis archive dc_b85a03ab7fe3, sha256 cd22ae03375fe22da48800fbb02027244a064e6f2fb5651fe09163357080d875)
BibTeX
@misc{dcb85a03ab7fe3,
  title = {SPARC: Slice-to-volume Pipeline for Automated Reconstruction of gated 3D+time fetal Cardiac MRI — arXiv:2608.18616},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2608.18616},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_b85a03ab7fe3; sha256 cd22ae03375fe22da48800fbb02027244a064e6f2fb5651fe09163357080d875},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.18616. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Fetal cardiac MRI (fCMR) provides valuable diagnostic information complementary to echocardiography, particularly for complex congenital heart disease (CHD). Dynamic cine imaging captures cardiac motion essential for assessment of cardiac function; however, the reconstruction of 3D+time cine volumes from 2D+time acquired slices remains challenging due to unpredictable fetal motion and the absence of automated and robust processing tools suitable for clinical deployment. We present the SPARC pipeline (Slice-to-volume Pipeline for Automated Reconstruction of gated 3D+time fetal Cardiac MRI) which combines physics-informed slice-to-volume reconstruction (SVR) of Doppler ultrasound (DUS) gated stacks of slices, assisted by deep learning (DL) models for thoracic segmentation and anatomical reorientation. The proposed SVR algorithm achieves a tenfold reduction in reconstruction time relative to existing frame-wise approaches ($4.8 \pm 1.0$ vs $49.0 \pm 14.1$ min, $p < 0.0001$) while improving the reconstruction quality. Thoracic segmentation performance using ensemble aggregation exceeded inter-rater agreement (Dice $84.7 \pm 3.9\%$ vs $81.4 \pm 7.7\%$, $p<0.05$), while anatomical reorientation achieved a success rate of $90.1\%$. End-to-end evaluation on a large held-out clinical cohort ($n = 121$) demonstrated fully automatic processing in $82.6\%$ of cases with a mean runtime of $7.1 \pm 1.3$ min, compatible with clinical deployment. The complete SPARC pipeline is publicly available as a Docker container this https URL and is currently deployed at our institution as a clinical research tool.

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-08-20 in cs.CV).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV).
Pagina del lavoro: https://arxiv.org/abs/2608.18616 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-18T14:00:22.563Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-08-20?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).