Metraipolis › archive › dc_b8496018f615
Change Point--Aware Evaluation and Re-Calibration of PPG-Based Blood Pressure Estimation — arXiv:2608.18639
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2608.18639
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-18T13:45:14.704Z
- SHA-256 of the archived text
3edc8debdb848cb1a7ea2beb329a06ff0edbe797e8c31d7319d7426674dda9df- Stable URL of this page
https://metraipolis.com/documento/dc_b8496018f615
How to cite
Change Point--Aware Evaluation and Re-Calibration of PPG-Based Blood Pressure Estimation — arXiv:2608.18639 — arXiv (en), https://arxiv.org/abs/2608.18639 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_b8496018f615 (Metraipolis archive dc_b8496018f615, sha256 3edc8debdb848cb1a7ea2beb329a06ff0edbe797e8c31d7319d7426674dda9df)
BibTeX
@misc{dcb8496018f615,
title = {Change Point--Aware Evaluation and Re-Calibration of PPG-Based Blood Pressure Estimation — arXiv:2608.18639},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2608.18639},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_b8496018f615; sha256 3edc8debdb848cb1a7ea2beb329a06ff0edbe797e8c31d7319d7426674dda9df},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.18639. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Non-invasive continuous blood pressure (BP) monitoring using photoplethysmography (PPG) is a promising alternative to cuff-based measurements. However, existing PPG-based BP estimation studies predominantly rely on aggregated performance metrics (e.g., mean absolute error) computed over entire evaluation intervals, which can obscure model failures during rapid BP fluctuations and limit clinical relevance. In this work, we propose a fluctuation-aware evaluation framework for PPG-based BP estimation based on time-series change point detection. Instead of heuristic BP thresholding (e.g., $\Delta\mathrm{BP} > 10\mathrm{mmHg}$), we identify BP change points by capturing abrupt distributional shifts in BP trajectories and evaluate estimation performance specifically during these fluctuation periods. Our analysis shows that several state-of-the-art models exhibit substantial performance degradation around BP change points, and that periodic test-time calibration is insufficient to handle such dynamic BP variations. To address this limitation, we introduce a targeted re-calibration framework triggered by detected BP change points, improving robustness without modifying model architectures. To the best of our knowledge, this is the first systematic evaluation of PPG-based BP estimation from a BP change point perspective, highlighting the importance of fluctuation-aware evaluation and calibration for real-world continuous BP monitoring.
Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-08-20 in cs.AI).
Categorie arXiv: Signal Processing (eess.SP) ; Artificial Intelligence (cs.AI); Machine Learning (cs.LG).
Pagina del lavoro: https://arxiv.org/abs/2608.18639 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-18T13:41:17.961Z dalla pagina https://arxiv.org/catchup/cs.AI/2026-08-20?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).