Metraipolis › archive › dc_b8410f0ac896
An Exact Noise Floor for Contingency-Table Effect Sizes: A Per-Table Reporting Gate, and How Often It Would Change Reported Magnitudes — arXiv:2609.26128
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.26128
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-08T15:50:22.563Z
- SHA-256 of the archived text
eb5058e1fde09b8d38cf23673b67a34035b48095db150da1b822529c8d3c03ae- Stable URL of this page
https://metraipolis.com/documento/dc_b8410f0ac896
How to cite
An Exact Noise Floor for Contingency-Table Effect Sizes: A Per-Table Reporting Gate, and How Often It Would Change Reported Magnitudes — arXiv:2609.26128 — arXiv (en), https://arxiv.org/abs/2609.26128 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_b8410f0ac896 (Metraipolis archive dc_b8410f0ac896, sha256 eb5058e1fde09b8d38cf23673b67a34035b48095db150da1b822529c8d3c03ae)
BibTeX
@misc{dcb8410f0ac896,
title = {An Exact Noise Floor for Contingency-Table Effect Sizes: A Per-Table Reporting Gate, and How Often It Would Change Reported Magnitudes — arXiv:2609.26128},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.26128},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_b8410f0ac896; sha256 eb5058e1fde09b8d38cf23673b67a34035b48095db150da1b822529c8d3c03ae},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.26128. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Cramer's V and the other chi-square-family effect sizes are positive under exact independence, so a reported value can be smaller than what the same statistic produces on a table with no association at all. The upward bias is classical (Tschuprow 1925; Bartlett 1937; corrected by Bergsma 2013), and reporting the boundary value, the critical effect size, beside the observed one has been recommended in general form (Perugini et al. 2025); we claim neither. Our contribution is two things a general recommendation does not supply. First, an exact per-table reporting gate: the noise floor V_0.95, the value the effect size reaches by chance 5% of the time under independence, computed from the exact margin-conditional law rather than the asymptotic critical value. The asymptotic floor miscalibrates where reporting is riskiest: on heterogeneous tables its false-alarm rate reaches 0.10 against a 0.05 target, while the exact floor holds nominal. Second, a measurement: across 4,129 real two-way tables from 291 public datasets, 21.8% of labeled effects (cluster-robust 95% CI 17 to 27%) sit on tables with no significant association. We recommend reporting V_0.95, in exact form on sparse or heterogeneous tables, beside every association measure and at the design stage. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-23 in stat.ME). Categorie arXiv: Methodology (stat.ME) ; Applications (stat.AP). Pagina del lavoro: https://arxiv.org/abs/2609.26128 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-08T15:07:51.396Z dalla pagina https://arxiv.org/catchup/stat.ME/2026-09-23?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).