Metraipolis › archive › dc_b81383d02ef6
DR-LiteNet: A Lightweight Explainable Hybrid CNN Framework for Imbalanced Diabetic Retinopathy Grading via Adaptive SMOTE Fusion — arXiv:2611.04405
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2611.04405
- License (as archived)
- CC0-1.0
- Archived
- 2026-11-04T19:03:13.259Z
- SHA-256 of the archived text
fef1eac81b648320b91b46b9fde74f238bbe2032d6525359fa12e6f9d9687092- Stable URL of this page
https://metraipolis.com/documento/dc_b81383d02ef6
How to cite
DR-LiteNet: A Lightweight Explainable Hybrid CNN Framework for Imbalanced Diabetic Retinopathy Grading via Adaptive SMOTE Fusion — arXiv:2611.04405 — arXiv (en), https://arxiv.org/abs/2611.04405 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_b81383d02ef6 (Metraipolis archive dc_b81383d02ef6, sha256 fef1eac81b648320b91b46b9fde74f238bbe2032d6525359fa12e6f9d9687092)
BibTeX
@misc{dcb81383d02ef6,
title = {DR-LiteNet: A Lightweight Explainable Hybrid CNN Framework for Imbalanced Diabetic Retinopathy Grading via Adaptive SMOTE Fusion — arXiv:2611.04405},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2611.04405},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_b81383d02ef6; sha256 fef1eac81b648320b91b46b9fde74f238bbe2032d6525359fa12e6f9d9687092},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.04405. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Automated diabetic retinopathy (DR) grading from colour fundus photographs is held back by two compounding challenges: severe class imbalance across five severity grades and the heavy computational cost of large scale architectures in resource constrained clinical settings. We introduce DR-LiteNet, a dual branch hybrid convolutional neural network that tackles both problems at once. The CNN branch extracts 1,280 dimensional deep features through EfficientNetB0, while the handcrafted (HC) branch produces a compact 51 dimensional lesion descriptor capturing vessel density, exudate intensity, texture entropy, and HSV colour histograms. Concatenating both branches yields a 1,331-d hybrid embedding, on which Adaptive SMOTE (ADASYN) is applied during training to synthesise minority class feature vectors, correcting distributional skew without touching the image space. A two phase training protocol first warms up the classification head on balanced features, then fine tunes the full network end to end. Grad CAM saliency maps deliver post-hoc clinical explainability. Tested on APTOS 2019 under five fold stratified cross validation, DR-LiteNet reaches 88.77% +/- 0.61 accuracy, a quadratic weighted kappa (QWK) of 0.884 +/- 0.010, and a macro F1 of 0.792 +/- 0.008 with only 4.69 M parameters beating ResNet50 (23.5 M) by DeltaQWK = 0.022 while staying practical on a single Google Colab T4 GPU. The source code of this project is available at: this https URL . Tema degli esploratori: statistica e scienza dei dati (elenco arXiv cs.CV, nuovi lavori del giorno). Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV). Pagina del lavoro: https://arxiv.org/abs/2611.04405 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-11-04T18:39:37.500Z dalla pagina https://arxiv.org/list/cs.CV/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).