Metraipolis › archive › dc_b641e750bf6b

Low Cost Eye Tracking for Vision Screening — arXiv:2609.31941

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.31941
License (as archived)
CC0-1.0
Archived
2026-10-08T00:16:51.775Z
SHA-256 of the archived text
5e703166067736ba7c0c5c3fffbe57bdc3ab4f661ec471e8bde028bba2d7b3a6
Stable URL of this page
https://metraipolis.com/documento/dc_b641e750bf6b

How to cite

Low Cost Eye Tracking for Vision Screening — arXiv:2609.31941 — arXiv (en), https://arxiv.org/abs/2609.31941 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_b641e750bf6b (Metraipolis archive dc_b641e750bf6b, sha256 5e703166067736ba7c0c5c3fffbe57bdc3ab4f661ec471e8bde028bba2d7b3a6)
BibTeX
@misc{dcb641e750bf6b,
  title = {Low Cost Eye Tracking for Vision Screening — arXiv:2609.31941},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.31941},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_b641e750bf6b; sha256 5e703166067736ba7c0c5c3fffbe57bdc3ab4f661ec471e8bde028bba2d7b3a6},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.31941. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

This engineering study assesses gaze-assisted data acquisition during visual screening with a Gaze Quest implementation via webcam and GC308 near infrared camera with an Orlosky eye tracking pipeline. Ten subjects performed under both acquisition conditions. Accuracy of Tumbling E orientation, reported application logMAR value,and response latency were determined from keyboard responses and hence are behavioral outputs as opposed toeye tracker screening results. Frame-to-frame change in theangle between successive normalized gaze vectors (28.2degrees) served as the GC308 eye tracker derived diagnostic with an effective sampling rate of roughly 8 FPS. No screen target calibration or gaze to screen translation was done on the GC308 eye tracker output data for the current analysis and hence, these data represent acquisition stability and not gaze accuracy in relation to the target. The webcam pipeline relied on 25-point screen calibration. Because the display resolution and pixel pitch could not be retained in the records of the study, the reported application logMAR values cannot be viewed as measures of visual acuity in any way.

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-29 in cs.RO).
Categorie arXiv: Robotics (cs.RO).
Pagina del lavoro: https://arxiv.org/abs/2609.31941 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-07T23:52:16.392Z dalla pagina https://arxiv.org/catchup/cs.RO/2026-09-29?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).