Metraipolis › archive › dc_b4dca0b88a05
Short-Circuit Current Calculation in DC Shipboard Microgrid Using Operational Admittances — arXiv:2611.00262
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2611.00262
- License (as archived)
- CC0-1.0
- Archived
- 2026-11-03T11:54:41.065Z
- SHA-256 of the archived text
99929d2d78c568f9a022ef13f1566126a796834294f9afc6815e4d0e7ba2fb56- Stable URL of this page
https://metraipolis.com/documento/dc_b4dca0b88a05
How to cite
Short-Circuit Current Calculation in DC Shipboard Microgrid Using Operational Admittances — arXiv:2611.00262 — arXiv (en), https://arxiv.org/abs/2611.00262 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_b4dca0b88a05 (Metraipolis archive dc_b4dca0b88a05, sha256 99929d2d78c568f9a022ef13f1566126a796834294f9afc6815e4d0e7ba2fb56)
BibTeX
@misc{dcb4dca0b88a05,
title = {Short-Circuit Current Calculation in DC Shipboard Microgrid Using Operational Admittances — arXiv:2611.00262},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2611.00262},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_b4dca0b88a05; sha256 99929d2d78c568f9a022ef13f1566126a796834294f9afc6815e4d0e7ba2fb56},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.00262. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
The increasing adoption of DC shipboard power systems is driven by the need to integrate energy storage systems seamlessly onboard. In this context, accurate calculation of short-circuit current transients is critical for sizing fast-acting protection devices. This paper proposes a methodology to calculate short-circuit current transients based on operational admittance modelling of network elements and power converters. The superposition principle is then applied to calculate current contributions and voltage time profiles. The methodology is validated with a detailed EMT model of a notional LVDC shipboard microgrid section consisting of an active front end, a bidirectional buck-boost converter and two special loads. Results demonstrate that the methodology accurately tracks nodal voltages and the fault current contributions dynamics up to the prospective fault current peak, thus providing a computationally efficient tool for fault analysis and protection coordination in LVDC microgrids. Tema degli esploratori: calcolo e infrastrutture (elenco arXiv eess.SY, nuovi lavori del giorno). Categorie arXiv: Systems and Control (eess.SY). Pagina del lavoro: https://arxiv.org/abs/2611.00262 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-11-03T11:15:22.661Z dalla pagina https://arxiv.org/list/eess.SY/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).