Metraipolis › archive › dc_b49c8607d899

A Controlled Comparison of Manual and Teleoperated Intraocular Instrument Motion for an Input Device — arXiv:2609.08770

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.08770
License (as archived)
CC0-1.0
Archived
2026-10-16T13:46:54.488Z
SHA-256 of the archived text
8544fec3811439697ced71faa70dcea7278e4f27ecbbe47b39a601ebbd06f54c
Stable URL of this page
https://metraipolis.com/documento/dc_b49c8607d899

How to cite

A Controlled Comparison of Manual and Teleoperated Intraocular Instrument Motion for an Input Device — arXiv:2609.08770 — arXiv (en), https://arxiv.org/abs/2609.08770 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_b49c8607d899 (Metraipolis archive dc_b49c8607d899, sha256 8544fec3811439697ced71faa70dcea7278e4f27ecbbe47b39a601ebbd06f54c)
BibTeX
@misc{dcb49c8607d899,
  title = {A Controlled Comparison of Manual and Teleoperated Intraocular Instrument Motion for an Input Device — arXiv:2609.08770},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.08770},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_b49c8607d899; sha256 8544fec3811439697ced71faa70dcea7278e4f27ecbbe47b39a601ebbd06f54c},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.08770. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Input devices for robotic microsurgery are frequently described as preserving the surgeon's trained technique, but the claim is rarely measured. We compared manual and teleoperated intraocular instrument motion with the trocar constraint, the instrument, the eye model and the tracking source common to both conditions, so that the control interface was the only factor varied. Prior comparisons cannot hold the instrument fixed, because a robotic instrument is not the tool used manually. Sixteen participants performed a navigation task on a commercial ophthalmic simulator by hand and through a three-degree-of-freedom input device commanding a five-joint robot. Task outcome was equal but at ceiling: every participant acquired all five targets under both interfaces with no retinal or lens injury. Execution differed on every measure. Teleoperated trials took three times as long at a quarter of the median speed, covered less than half the angular working range, and were broken into 3.5 times as many separate movements. Completion time and movement fragmentation improved substantially across four trials of practice and had not plateaued; the measures set by the configured rate ceiling and joint limit changed the least. Finger activity doubled and pinch variability tripled, so reducing instrument degrees of freedom redistributed manual effort rather than reducing it. The interface preserves the outcome and reshapes the execution.

Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-09 in cs.HC).
Categorie arXiv: Robotics (cs.RO) ; Human-Computer Interaction (cs.HC).
Pagina del lavoro: https://arxiv.org/abs/2609.08770 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-16T13:28:43.173Z dalla pagina https://arxiv.org/catchup/cs.HC/2026-09-09?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).