Metraipolis › archive › dc_b48847c152e9
UMPIRE-Net: Unrolled Magnitude-Phase Regularization Network for Accelerated MRI — arXiv:2608.14422
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2608.14422
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-19T04:04:38.555Z
- SHA-256 of the archived text
1dc8d493570aa5088c75ffd79d2643ec317b151b0bb55ffdfd37db1553c55cdf- Stable URL of this page
https://metraipolis.com/documento/dc_b48847c152e9
How to cite
UMPIRE-Net: Unrolled Magnitude-Phase Regularization Network for Accelerated MRI — arXiv:2608.14422 — arXiv (en), https://arxiv.org/abs/2608.14422 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_b48847c152e9 (Metraipolis archive dc_b48847c152e9, sha256 1dc8d493570aa5088c75ffd79d2643ec317b151b0bb55ffdfd37db1553c55cdf)
BibTeX
@misc{dcb48847c152e9,
title = {UMPIRE-Net: Unrolled Magnitude-Phase Regularization Network for Accelerated MRI — arXiv:2608.14422},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2608.14422},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_b48847c152e9; sha256 1dc8d493570aa5088c75ffd79d2643ec317b151b0bb55ffdfd37db1553c55cdf},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.14422. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
MRI reconstruction from undersampled k-space measurements is an ill-posed inverse problem. Physics-driven deep learning (PD-DL) methods have shown strong performance for this task by combining the MRI forward model with learned image regularization within algorithm-unrolling frameworks. However, most existing PD-DL methods reconstruct complex-valued images directly, thereby implicitly coupling magnitude and phase within a single learned representation. This coupled regularization may be suboptimal in reconstruction settings where accurate phase modeling plays an important role, such as partial Fourier (PF) imaging, where recovery of the omitted asymmetric k-space measurements depends on the underlying image phase. In such scenarios, explicit modeling of magnitude and phase as separate components may reduce the reliance on externally estimated or predefined phase information. To this end, we propose UMPIRE-Net (Unrolled Magnitude-Phase In REgularization Network), a PD-DL method that introduces separate learned regularizers for magnitude and phase components, together with a novel data-fidelity formulation that enforces measurements consistency. We evaluate UMPIRE-Net for accelerated MRI with PF across different datasets and acceleration factors. Experimental results demonstrate that our proposed method improves reconstruction quality compared with a conventional complex-valued PD-DL baseline, yielding sharper images and reduced artifacts. Code available at: this https URL Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-08-17 in cs.CV). Categorie arXiv: Image and Video Processing (eess.IV) ; Computer Vision and Pattern Recognition (cs.CV); Signal Processing (eess.SP); Medical Physics (physics.med-ph). Pagina del lavoro: https://arxiv.org/abs/2608.14422 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-19T03:57:58.050Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-08-17?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).