Metraipolis › archive › dc_b3772a6e6491
Faithful Faithfulness Evaluations: Challenges & Pitfalls Learned from a Breast MRI Case Study — arXiv:2609.25978
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.25978
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-08T15:07:03.394Z
- SHA-256 of the archived text
77cfa01fb61853b743510437e63766288806fcc52746450757b8f0775b2fd58c- Stable URL of this page
https://metraipolis.com/documento/dc_b3772a6e6491
How to cite
Faithful Faithfulness Evaluations: Challenges & Pitfalls Learned from a Breast MRI Case Study — arXiv:2609.25978 — arXiv (en), https://arxiv.org/abs/2609.25978 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_b3772a6e6491 (Metraipolis archive dc_b3772a6e6491, sha256 77cfa01fb61853b743510437e63766288806fcc52746450757b8f0775b2fd58c)
BibTeX
@misc{dcb3772a6e6491,
title = {Faithful Faithfulness Evaluations: Challenges & Pitfalls Learned from a Breast MRI Case Study — arXiv:2609.25978},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.25978},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_b3772a6e6491; sha256 77cfa01fb61853b743510437e63766288806fcc52746450757b8f0775b2fd58c},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.25978. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Saliency maps are widely used to explain deep learning predictions in medical imaging, yet visually plausible explanations do not necessarily reflect a model's true decision process and may therefore mislead clinicians. We investigate this problem using a Vision Transformer-based breast MRI classifier trained on the ODELIA Breast MRI Challenge dataset and evaluate multiple saliency methods, including Last-layer Attention, Attention Rollout, Grad-SAM, Gradient Attention Rollout, GMAR, Grad-CAM, and HiResCAM. Our study highlights two often-overlooked challenges in perturbation-based faithfulness evaluation. First, method rankings depend strongly on the perturbation strategy, varying across intensity-based perturbations and transformer-based attention masking. Second, benchmarking saliency methods requires distinguishing between class-specific and class-agnostic explanations. To enable fair comparisons, we introduce non-class-specific variants of gradient-based methods and evaluate both settings separately. Across protocols, Grad-CAM and Gradient Attention Rollout consistently emerged as the strongest class-specific methods, although their relative ranking depended on the evaluation design. These findings expose important limitations of current saliency-based explainability approaches and highlight the need for more robust and standardized evaluation frameworks for trustworthy clinical AI systems. Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-23 in cs.HC). Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV) ; Human-Computer Interaction (cs.HC); Machine Learning (cs.LG); Image and Video Processing (eess.IV). Pagina del lavoro: https://arxiv.org/abs/2609.25978 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-08T14:34:31.488Z dalla pagina https://arxiv.org/catchup/cs.HC/2026-09-23?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).