Metraipolis › archive › dc_b198267fa3d8
Measure Before You Repair: An Explainable Agent for Blind Restoration of Multi-Artifact 3-D MRI — arXiv:2611.03996
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2611.03996
- License (as archived)
- CC0-1.0
- Archived
- 2026-11-04T21:39:46.303Z
- SHA-256 of the archived text
b9e5b66bf0a4adb3c60354cbcff59f8eec693a58ca1a67a45ae8978e9bb78d01- Stable URL of this page
https://metraipolis.com/documento/dc_b198267fa3d8
How to cite
Measure Before You Repair: An Explainable Agent for Blind Restoration of Multi-Artifact 3-D MRI — arXiv:2611.03996 — arXiv (en), https://arxiv.org/abs/2611.03996 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_b198267fa3d8 (Metraipolis archive dc_b198267fa3d8, sha256 b9e5b66bf0a4adb3c60354cbcff59f8eec693a58ca1a67a45ae8978e9bb78d01)
BibTeX
@misc{dcb198267fa3d8,
title = {Measure Before You Repair: An Explainable Agent for Blind Restoration of Multi-Artifact 3-D MRI — arXiv:2611.03996},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2611.03996},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_b198267fa3d8; sha256 b9e5b66bf0a4adb3c60354cbcff59f8eec693a58ca1a67a45ae8978e9bb78d01},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.03996. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
A brain MRI scan can carry an unknown mix of artifacts, so restoration has to be blind, yet most deep-learning methods are built to correct one known artifact. We present Dx-Rx, an agent in which a multimodal large language model (MLLM) measures suspected artifacts before it repairs them. To our knowledge, it is the first agent to restore whole 3-D MRI volumes, whereas earlier MRI agents restore 2-D slices. In a loop, it looks at slices of the 3-D volume, calls five diagnostic tools (noise, spike, ghosting, bias field, motion) and four restoration tools in any order it chooses, checks each repair, can return to any earlier version to change the order, and ends with a radiology-style report of its diagnostic reasons, the repairs it applied and their results. We simulated up to five artifacts on 148 whole 3-D T1-weighted volumes, at levels calibrated to radiologists' grades of real scans. An MLLM that only looked at the image, as earlier MRI agents do, removed at most 19.7 % of the artifact error. With the best of five MLLMs, Dx-Rx removed a mean 64.5 %, nearly matching the 64.6 % of the same tools given the ground-truth artifacts, which are never known for a clinical scan. With all five models, it made no volume worse and was on par with or better than an expert rule-based pipeline built from the same tools (62.3 %). Code and demo are public at this https URL . Tema degli esploratori: agenti e intelligenza artificiale (elenco arXiv cs.AI, nuovi lavori del giorno). Categorie arXiv: Image and Video Processing (eess.IV) ; Artificial Intelligence (cs.AI). Pagina del lavoro: https://arxiv.org/abs/2611.03996 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-11-04T21:35:49.636Z dalla pagina https://arxiv.org/list/cs.AI/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).