Metraipolis › archive › dc_b0b4466e88ab
High level of HIV false positives using EIA-based algorithm in survey: Importance of confirmatory testing — Europe PMC PMID:33091019
- Source
- Europe PMC (en)
- Original
- https://europepmc.org/article/MED/33091019
- DOI
- 10.1371/journal.pone.0239782
- License (as archived)
- CC0-1.0
- Archived
- 2026-11-07T02:41:22.751Z
- SHA-256 of the archived text
f80e0503c06b7379d080c3d56ecd1ed1c140768ebe58b77c549c88abadfeb105- Stable URL of this page
https://metraipolis.com/documento/dc_b0b4466e88ab
How to cite
High level of HIV false positives using EIA-based algorithm in survey: Importance of confirmatory testing — Europe PMC PMID:33091019 — Europe PMC (en), https://europepmc.org/article/MED/33091019 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_b0b4466e88ab (Metraipolis archive dc_b0b4466e88ab, sha256 f80e0503c06b7379d080c3d56ecd1ed1c140768ebe58b77c549c88abadfeb105)
BibTeX
@misc{dcb0b4466e88ab,
title = {High level of HIV false positives using EIA-based algorithm in survey: Importance of confirmatory testing — Europe PMC PMID:33091019},
howpublished = {Europe PMC (en)},
url = {https://europepmc.org/article/MED/33091019},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_b0b4466e88ab; sha256 f80e0503c06b7379d080c3d56ecd1ed1c140768ebe58b77c549c88abadfeb105},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: Europe PMC (en), https://europepmc.org/article/MED/33091019. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
The Mozambique Indicators of Immunization, Malaria and HIV/AIDS (IMASIDA) survey was conducted in 2015 and used a two Enzyme Immunoassay (EIA) (Vironostika HIV-1/2 and Murex HIV-1/2) based algorithm to determine the HIV status of the consented participants. The Mozambique Ministry of Health, with support from the US Centers for Disease Control and Prevention (US CDC), added Bio-Rad Geenius™ HIV-1/2 Supplemental Assay to the IMASIDA HIV testing algorithm to confirm all specimens that were found to be reactive on one or both EIAs. In total 11690 specimens were collected to estimate the proportion of HIV positive samples. Results indicate that the proportion of HIV positive samples based on the concordant positive results of two EIA assays was 21.5% (2518/11690). The addition of the Geenius assay to the IMASIDA HIV testing algorithm demonstrated that 792 (31.5%) of 2518 specimens were false-positive and reduced the proportion of HIV positive samples to 14.7% (1722/11690), demonstrating the importance of including a highly specific HIV test to confirm HIV diagnosis. HIV surveys exclusively based on EIA testing algorithm may result in misleading high prevalence results. Our results demonstrate that more specific confirmatory testing should be added to the EIA-based algorithms to ensure accurate HIV diagnosis and correct HIV prevalence estimate in cross-sectional surveys. Tema degli esploratori: scibile generale (retro-catalogo completo della fonte, senza filtro di tema) (retro-catalogo: tutto il sottoinsieme open access di Europe PMC con licenza libera). Pubblicazione: PloS one, 2020 (prima pubblicazione 2020-10-22). Identificativi: PMID 33091019 · PMCID PMC7580971 · DOI 10.1371/journal.pone.0239782. Descrittori MeSH principali: Immunoenzyme Techniques. Pagina: https://europepmc.org/article/MED/33091019 — https://doi.org/10.1371/journal.pone.0239782. Autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza dell'articolo dichiarata da Europe PMC: CC0 (la versione è indicata dall'editore sulla pagina). Abstract riportato senza modifiche al contenuto, con attribuzione; deposito marcato CC0. Letto il 2026-11-07T02:37:45.980Z tramite l'API REST ufficiale di Europe PMC (EMBL-EBI), nel rispetto del robots.txt e del crawl-delay.