Metraipolis › archive › dc_afff8022ee92
Calibration-First Cross-Cohort Multimodal Temporal Learning for Transferable Asthma-Risk Forecasting — arXiv:2609.35795
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.35795
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-07T16:24:36.667Z
- SHA-256 of the archived text
fb031f072a7fbe134197f7dc3b27e96a386a0205998de1e0888cc4fd618857b8- Stable URL of this page
https://metraipolis.com/documento/dc_afff8022ee92
How to cite
Calibration-First Cross-Cohort Multimodal Temporal Learning for Transferable Asthma-Risk Forecasting — arXiv:2609.35795 — arXiv (en), https://arxiv.org/abs/2609.35795 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_afff8022ee92 (Metraipolis archive dc_afff8022ee92, sha256 fb031f072a7fbe134197f7dc3b27e96a386a0205998de1e0888cc4fd618857b8)
BibTeX
@misc{dcafff8022ee92,
title = {Calibration-First Cross-Cohort Multimodal Temporal Learning for Transferable Asthma-Risk Forecasting — arXiv:2609.35795},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.35795},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_afff8022ee92; sha256 fb031f072a7fbe134197f7dc3b27e96a386a0205998de1e0888cc4fd618857b8},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.35795. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Asthma deterioration forecasting must remain reli- able when patient populations, sensor ecosystems, and available modalities change across cohorts. Existing models commonly optimize within-cohort discrimination and may produce poorly calibrated probabilities after transfer. We present CALIBRA, a calibration-first multimodal temporal framework for short- horizon risk prediction with incomplete data. Dedicated recurrent encoders process environmental, pulmonary, symptom, medication, wearable, and context streams; a reliability-conditioned gate suppresses stale or absent modalities, while gradient-reversal training discourages avoidable cohort signatures. A shrinkage- based hierarchical logistic layer calibrates probabilities using a patient-disjoint target subset, and split conformal prediction provides abstention-capable prediction sets. To avoid fabricating clinical evidence, we evaluate the complete implementation on a documented three-cohort semi-synthetic benchmark with controlled distribution shift, informative missingness, and sealed target patients. Across five configured seeds, CALIBRA achieved mean target-test AUPRC 0.224 versus 0.240 for the strongest non-ablation comparator, TemporalTransformer; mean AUROC was 0.717, and Brier score was 0.098. Experiments additionally assess complete-modality failures, calibration, conformal coverage, decision curves, subgroup behavior, ablations, runtime, and parameter count. The results verify the method and reproducible pipeline under controlled shift, but do not establish clinical effectiveness. External validation on harmonized real asthma. Overall this artifact provides evidence for carefully governed real-cohort validation. Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-30 in cs.AI). Categorie arXiv: Machine Learning (cs.LG) ; Artificial Intelligence (cs.AI). Pagina del lavoro: https://arxiv.org/abs/2609.35795 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-07T15:54:53.701Z dalla pagina https://arxiv.org/catchup/cs.AI/2026-09-30?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).