Metraipolis › archive › dc_af9224ffd9cb
Splat-Based Metal Artifact Reduction in Cone-Beam CT via Compact Attenuation Modeling — arXiv:2608.04764
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2608.04764
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-31T11:48:08.437Z
- SHA-256 of the archived text
b8c24681ee8c708846cc0d97ed1c4903adf226209a6362444918404dfd77dbc7- Stable URL of this page
https://metraipolis.com/documento/dc_af9224ffd9cb
How to cite
Splat-Based Metal Artifact Reduction in Cone-Beam CT via Compact Attenuation Modeling — arXiv:2608.04764 — arXiv (en), https://arxiv.org/abs/2608.04764 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_af9224ffd9cb (Metraipolis archive dc_af9224ffd9cb, sha256 b8c24681ee8c708846cc0d97ed1c4903adf226209a6362444918404dfd77dbc7)
BibTeX
@misc{dcaf9224ffd9cb,
title = {Splat-Based Metal Artifact Reduction in Cone-Beam CT via Compact Attenuation Modeling — arXiv:2608.04764},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2608.04764},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_af9224ffd9cb; sha256 b8c24681ee8c708846cc0d97ed1c4903adf226209a6362444918404dfd77dbc7},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.04764. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
X-ray computed tomography (CT) suffers from severe metal artifacts when high-attenuation objects such as dental fillings or orthopedic implants are present. These artifacts originate from the polychromatic nature of X-rays, where attenuation varies strongly with photon energy and material composition, breaking the monochromatic assumption used by conventional reconstruction algorithms. Recent neural rendering approaches attempt to address this mismatch through differentiable polychromatic projection models, but they still struggle with smoothness bias, loss of fine structures, and prohibitive computation when extended to large-scale cone-beam CT. We introduce a splat-based metal artifact reduction framework that incorporates a physically grounded polychromatic forward model into a continuous Gaussian representation for cone-beam CT. Each Gaussian encodes the energy-dependent attenuation of the underlying material using a compact material parameterization, which enables efficient joint optimization of geometric and material properties without relying on a metal mask. This compact attenuation formulation captures the essential variation across biological tissues and metallic implants, allowing our model to explain metal-induced nonlinearity while preserving high-frequency structure. Experiments on simulated and real cone-beam CT scans show that our method converges significantly faster and suppresses metal artifacts more effectively than existing reconstruction and neural field-based approaches. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-08-06 in cs.CV). Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV) ; Graphics (cs.GR). Pagina del lavoro: https://arxiv.org/abs/2608.04764 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-31T11:37:40.713Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-08-06?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).