Metraipolis › archive › dc_af6a37eb0a3f

A Dry-Contact Ear-EEG System With Continuous Electrode-Skin Impedance Mismatch Monitoring for Motion Artifact Cancellation Using DRL Stimulus — arXiv:2609.02777

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.02777
License (as archived)
CC0-1.0
Archived
2026-10-17T06:30:04.187Z
SHA-256 of the archived text
618a8fe37072c43bef2be97d537a410db97911cae28b3dd4eab9762564d04d15
Stable URL of this page
https://metraipolis.com/documento/dc_af6a37eb0a3f

How to cite

A Dry-Contact Ear-EEG System With Continuous Electrode-Skin Impedance Mismatch Monitoring for Motion Artifact Cancellation Using DRL Stimulus — arXiv:2609.02777 — arXiv (en), https://arxiv.org/abs/2609.02777 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_af6a37eb0a3f (Metraipolis archive dc_af6a37eb0a3f, sha256 618a8fe37072c43bef2be97d537a410db97911cae28b3dd4eab9762564d04d15)
BibTeX
@misc{dcaf6a37eb0a3f,
  title = {A Dry-Contact Ear-EEG System With Continuous Electrode-Skin Impedance Mismatch Monitoring for Motion Artifact Cancellation Using DRL Stimulus — arXiv:2609.02777},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.02777},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_af6a37eb0a3f; sha256 618a8fe37072c43bef2be97d537a410db97911cae28b3dd4eab9762564d04d15},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.02777. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Dry-contact ear-electroencephalography (Ear-EEG) enables wearable neural monitoring. However, motion induced electrode-skin impedance (ESI) mismatches between electrodes can severely degrade signal quality. To the best of our knowledge, this paper presents the first proof-of-concept dry-contact EarEEG system that uses a driven-right-leg (DRL) stimulus for continuous ESI mismatch monitoring, enabling online adaptive motion artifact cancellation. A 1 kHz sinusoidal stimulus is injected through the DRL electrode. The resulting response to the injected carrier is separated from the EEG using bandpass filtering and demodulation, and then used to extract the ESI mismatch information as the reference input for a normalized least-mean-square adaptive filter followed by a Hampel filtering stage. To evaluate artifact suppression and preservation of neural activity, alpha-band EEG activity was analyzed involving four healthy participants performing head nodding, electrode tapping, and jaw clenching. The system achieved artifact power reductions of 6.5, 12.6, and 9.0 dB (77.6%, 92.8%, and 86.4%, respectively) while alpha-band modulation remained clearly observable after processing. This demonstrates the feasibility of DRL-stimulusbased ESI mismatch monitoring for motion artifact cancellation in wearable dry-contact Ear-EEG.

Tema degli esploratori: calcolo e infrastrutture (retro-catalogo arXiv: annunci del 2026-09-03 in eess.SY).
Categorie arXiv: Signal Processing (eess.SP) ; Systems and Control (eess.SY).
Pagina del lavoro: https://arxiv.org/abs/2609.02777 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-17T06:13:51.292Z dalla pagina https://arxiv.org/catchup/eess.SY/2026-09-03?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).