Metraipolis › archive › dc_af4f3470c996
Performance Limits and Tradeoffs of Power Systems Synchronization Recovery in Complex-Frequency Representation — arXiv:2610.02719
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2610.02719
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-06T11:41:42.813Z
- SHA-256 of the archived text
0248d352d26f5415cfc9e809321e6c6505a81f5cfdb0647ebc3648b9fa7afa3c- Stable URL of this page
https://metraipolis.com/documento/dc_af4f3470c996
How to cite
Performance Limits and Tradeoffs of Power Systems Synchronization Recovery in Complex-Frequency Representation — arXiv:2610.02719 — arXiv (en), https://arxiv.org/abs/2610.02719 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_af4f3470c996 (Metraipolis archive dc_af4f3470c996, sha256 0248d352d26f5415cfc9e809321e6c6505a81f5cfdb0647ebc3648b9fa7afa3c)
BibTeX
@misc{dcaf4f3470c996,
title = {Performance Limits and Tradeoffs of Power Systems Synchronization Recovery in Complex-Frequency Representation — arXiv:2610.02719},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2610.02719},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_af4f3470c996; sha256 0248d352d26f5415cfc9e809321e6c6505a81f5cfdb0647ebc3648b9fa7afa3c},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.02719. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Power-system synchronization studies mainly ask whether synchronization can be achieved, whereas a complementary question is how well post-disturbance synchronization recovery can be shaped. In inverter-dominated systems, this recovery involves coupled phase-angle and voltage-magnitude dynamics, for which complex frequency provides a unified representation. This paper establishes a conservation law for synchronization recovery in this representation. For a given system and its initial state, the logarithmic integral of the proposed recovery residual is fixed by the initial contraction rate and the right-half-plane (RHP) zero--pole structure. Hence, synchronization recovery performance cannot be improved uniformly over frequencies and variables unless the budget set by these terms changes; controller tuning that preserves them can only redistribute the residual response across frequencies. The conservation law applies to both linear and nonlinear recovery responses satisfying the mild analyticity conditions. It further yields finite-frequency peak--bandwidth limits and a lower bound on the time-domain integral of squared complex frequency recovery. A system-level extension recovers classical Bode-type sensitivity conservation as an LTI special case. Studies on a heterogeneous IEEE 39-bus system verify the theory. Tema degli esploratori: calcolo e infrastrutture (retro-catalogo arXiv: annunci del 2026-10-05 in eess.SY). Categorie arXiv: Systems and Control (eess.SY). Pagina del lavoro: https://arxiv.org/abs/2610.02719 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-06T10:05:37.582Z dalla pagina https://arxiv.org/catchup/eess.SY/2026-10-05?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).