Metraipolis › archive › dc_aedd9d7455dd

Finite-energy Gottesman-Kitaev-Preskill state-enhanced optical interferometry — arXiv:2609.09227

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.09227
License (as archived)
CC0-1.0
Archived
2026-10-16T11:20:51.173Z
SHA-256 of the archived text
b60990551a06c3901ba5cdbf3e8ae335cbc79d19b421da5a78c92d12cf26e158
Stable URL of this page
https://metraipolis.com/documento/dc_aedd9d7455dd

How to cite

Finite-energy Gottesman-Kitaev-Preskill state-enhanced optical interferometry — arXiv:2609.09227 — arXiv (en), https://arxiv.org/abs/2609.09227 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_aedd9d7455dd (Metraipolis archive dc_aedd9d7455dd, sha256 b60990551a06c3901ba5cdbf3e8ae335cbc79d19b421da5a78c92d12cf26e158)
BibTeX
@misc{dcaedd9d7455dd,
  title = {Finite-energy Gottesman-Kitaev-Preskill state-enhanced optical interferometry — arXiv:2609.09227},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.09227},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_aedd9d7455dd; sha256 b60990551a06c3901ba5cdbf3e8ae335cbc79d19b421da5a78c92d12cf26e158},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.09227. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

We present the case of a Gottesman-Kitaev-Preskill (GKP) state-enhanced optical interferometry with detailed analysis of the phase sensitivity for both the SU(2) and SU(1,1) interferometers. The conventional quantum-enhanced SU(2) interferometer, employing coherent light at one input port and squeezed light at the other, is compared with a modified configuration using coherent light and a GKP state. While it is known that the squeezed vacuum state is the optimal Gaussian resource input mode when paired with the coherent state, we show that the finite-energy GKP state with sufficiently broad envelope outperforms the squeezed vacuum injection, irrespective of the presence of optical losses. This can be attributed to the enhanced robustness coming from the availability of multiple squeezed peaks in the GKP case. However, because lowering the mean photon number reduces the GKP envelope width, the squeezed vacuum input performs better when compared with a GKP state of equal or lower mean photon number. We also observe that optical losses tend to diminish the relative advantage of either input state, since both states approach the (unsqueezed) vacuum state asymptotically. Our work demonstrates the direct application of finite-energy GKP states in optical interferometry along with a methodology for estimating the quantum Fisher information (QFI) and presents a phase estimation procedure using non-Gaussian resources in comparison with conventional Gaussian states.

Tema degli esploratori: fisica e astronomia (retro-catalogo arXiv: annunci del 2026-09-10 in quant-ph).
Categorie arXiv: Quantum Physics (quant-ph).
Pagina del lavoro: https://arxiv.org/abs/2609.09227 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-16T11:00:36.153Z dalla pagina https://arxiv.org/catchup/quant-ph/2026-09-10?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).