Metraipolis › archive › dc_aed1d6ec5005

Analytically Corrected Bayesian Modularization for Local Item Calibration — arXiv:2608.11542

Source
arXiv (en)
Original
https://arxiv.org/abs/2608.11542
License (as archived)
CC0-1.0
Archived
2026-10-19T05:43:16.996Z
SHA-256 of the archived text
69fef8c21f92034dc13c962200f60810a882cf8ed8fc2948a195d2bee318b6ff
Stable URL of this page
https://metraipolis.com/documento/dc_aed1d6ec5005

How to cite

Analytically Corrected Bayesian Modularization for Local Item Calibration — arXiv:2608.11542 — arXiv (en), https://arxiv.org/abs/2608.11542 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_aed1d6ec5005 (Metraipolis archive dc_aed1d6ec5005, sha256 69fef8c21f92034dc13c962200f60810a882cf8ed8fc2948a195d2bee318b6ff)
BibTeX
@misc{dcaed1d6ec5005,
  title = {Analytically Corrected Bayesian Modularization for Local Item Calibration — arXiv:2608.11542},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2608.11542},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_aed1d6ec5005; sha256 69fef8c21f92034dc13c962200f60810a882cf8ed8fc2948a195d2bee318b6ff},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.11542. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

The continuous calibration of pilot items embedded in operational assessments is challenging when pilot samples are small and adaptively routed. We formalize a Bayesian modularization framework for local item calibration that blocks feedback from pilot responses to the operational latent scale: Plausible Values are drawn from the operational posterior, and each pilot item is calibrated by its own local logistic regression. This construction is computationally scalable, protects operational trait estimates from malfunctioning pilot items, and admits Firth's penalized likelihood for sparse routed samples. Because treating imputed traits as fixed predictors induces attenuation, we derive closed-form disattenuation mappings that recover the generating item parameters under normal-ogive, posterior-normality, homoscedasticity, and joint-normality approximations. The resulting Modular Local Calibration (MLC) estimator reaches the target of marginal-likelihood calibration without per-item numerical integration. A multivariate delta-method covariance combined with Rubin's-rules pooling propagates operational item-parameter uncertainty into the focal item standard errors. Monte Carlo simulations for the unidimensional 2PL show that corrected MLC substantially reduces attenuation bias and yields nominal-to-conservative interval coverage in the studied conditions, including under restricted-range MAR routing.

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-08-13 in stat.ME).
Categorie arXiv: Methodology (stat.ME) ; Applications (stat.AP).
Pagina del lavoro: https://arxiv.org/abs/2608.11542 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-19T05:32:03.748Z dalla pagina https://arxiv.org/catchup/stat.ME/2026-08-13?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).