Metraipolis › archive › dc_aeb950e70c01

Dynamic Centrality Measures for Water Distribution Network Hydraulics — arXiv:2609.10800

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.10800
License (as archived)
CC0-1.0
Archived
2026-10-16T06:01:11.075Z
SHA-256 of the archived text
f1230450e12d9380f008ee4c43a6dfdc7333d4372f5a6d644a7826b546602582
Stable URL of this page
https://metraipolis.com/documento/dc_aeb950e70c01

How to cite

Dynamic Centrality Measures for Water Distribution Network Hydraulics — arXiv:2609.10800 — arXiv (en), https://arxiv.org/abs/2609.10800 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_aeb950e70c01 (Metraipolis archive dc_aeb950e70c01, sha256 f1230450e12d9380f008ee4c43a6dfdc7333d4372f5a6d644a7826b546602582)
BibTeX
@misc{dcaeb950e70c01,
  title = {Dynamic Centrality Measures for Water Distribution Network Hydraulics — arXiv:2609.10800},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.10800},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_aeb950e70c01; sha256 f1230450e12d9380f008ee4c43a6dfdc7333d4372f5a6d644a7826b546602582},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.10800. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Water distribution networks (WDNs) are susceptible to various failures, including but not limited to human errors, cyber-attacks, and network modifications, necessitating the vulnerability analysis of WDNs. Graph-theoretic centrality measures---as a main class of centrality measures---aim to rank the network components solely based on their influence (i.e., criticality) on the WDN topology in the case of input changes, while overlooking the WDN dynamics. To overcome such a limitation, this paper uses a control-theoretic centrality measure to identify the network's most and least influential pipes in WDNs, by simultaneously incorporating the dynamics and topology of the WDN. First, given a WDN modeled by nonlinear differential-algebraic equations (NDAEs) consisting of transient flow dynamics as differential equation (DE) and conservation of water mass as algebraic equation (AE) and considering the pipe flow rates as states of the state-space (SS) representation, we extract a linearized system modeled by linear ordinary differential equations (LODEs) around the equilibrium (i.e., steady) flow rate vector. Second, treating pipe flow rates as SS nodes (states), we introduce a node centrality-based measure, namely \textit{vulnerability vector (VV)}, to rank the network pipes based on their influence on the dynamics and topology of the WDN in the case of input changes. In particular, the network's most and least influential pipes can be identified through such a centrality-based approach. This enables water engineers to understand the WDN's vulnerability better and effectively prioritize the maintenance and operational efforts on the most influential pipes within the WDN.

Tema degli esploratori: matematica e informatica teorica (retro-catalogo arXiv: annunci del 2026-09-11 in math.OC).
Categorie arXiv: Systems and Control (eess.SY) ; Optimization and Control (math.OC).