Metraipolis › archive › dc_ae48fa25961d
Frequency-Dependent Breakdown of Litz-Wire Insulation Under Repetitive Bipolar Square-Wave Voltages — arXiv:2610.07012
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2610.07012
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-07T21:07:02.909Z
- SHA-256 of the archived text
eb49d0e7201f5cec54da00cacddffbf84afac275eaf614e2c5b23f335046ceef- Stable URL of this page
https://metraipolis.com/documento/dc_ae48fa25961d
How to cite
Frequency-Dependent Breakdown of Litz-Wire Insulation Under Repetitive Bipolar Square-Wave Voltages — arXiv:2610.07012 — arXiv (en), https://arxiv.org/abs/2610.07012 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_ae48fa25961d (Metraipolis archive dc_ae48fa25961d, sha256 eb49d0e7201f5cec54da00cacddffbf84afac275eaf614e2c5b23f335046ceef)
BibTeX
@misc{dcae48fa25961d,
title = {Frequency-Dependent Breakdown of Litz-Wire Insulation Under Repetitive Bipolar Square-Wave Voltages — arXiv:2610.07012},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2610.07012},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_ae48fa25961d; sha256 eb49d0e7201f5cec54da00cacddffbf84afac275eaf614e2c5b23f335046ceef},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.07012. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
This paper investigates the dielectric breakdown behavior of Litz wire insulation subjected to repetitive fast-edge bipolar square-wave voltages representative of wide-bandgap (WBG) power converter stress. Two conductor sizes, 14 AWG and 16 AWG, were tested in a twisted-pair configuration over frequencies ranging from 1 kHz to 30 kHz using a controlled high-voltage pulse generator with 200 ns rise time. The breakdown voltages obtained at each frequency were statistically analyzed using the weighted two-parameter Weibull method in accordance with IEEE Std 930-2004. Between 1 and 30 kHz, the mean breakdown voltage decreases by approximately 10.7% for the 14 AWG construction and 20.0% for the 16 AWG construction. The 14 AWG specimens exhibit a modest increase between 1 and 5 kHz followed by a decline, whereas the 16 AWG mean decreases across the tested frequencies. The Weibull shape parameter varies nonmonotonically with frequency, characterizing differences in the dispersion of the measured breakdown voltages. These findings provide construction-specific breakdown data relevant to Litz-wire insulation assessment in high-frequency power electronic applications. Possible contributions from charge accumulation, localized discharge activity, and dielectric heating are discussed, but were not directly verified in this study. Tema degli esploratori: calcolo e infrastrutture (elenco arXiv eess.SY, nuovi lavori del giorno). Categorie arXiv: Systems and Control (eess.SY) ; Materials Science (cond-mat.mtrl-sci). Pagina del lavoro: https://arxiv.org/abs/2610.07012 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-07T20:38:49.018Z dalla pagina https://arxiv.org/list/eess.SY/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).