Metraipolis › archive › dc_ad7967e7b7d4
Validation of HRV Studio: A Transparent and Quality-Control-Aware Platform for Heart Rate Variability Analysis — arXiv:2608.24241
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2608.24241
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-18T06:36:52.464Z
- SHA-256 of the archived text
3bf7baf875864509b57b7c1676a9eb6d3b8246da1f9625e71e195335b58e44ad- Stable URL of this page
https://metraipolis.com/documento/dc_ad7967e7b7d4
How to cite
Validation of HRV Studio: A Transparent and Quality-Control-Aware Platform for Heart Rate Variability Analysis — arXiv:2608.24241 — arXiv (en), https://arxiv.org/abs/2608.24241 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_ad7967e7b7d4 (Metraipolis archive dc_ad7967e7b7d4, sha256 3bf7baf875864509b57b7c1676a9eb6d3b8246da1f9625e71e195335b58e44ad)
BibTeX
@misc{dcad7967e7b7d4,
title = {Validation of HRV Studio: A Transparent and Quality-Control-Aware Platform for Heart Rate Variability Analysis — arXiv:2608.24241},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2608.24241},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_ad7967e7b7d4; sha256 3bf7baf875864509b57b7c1676a9eb6d3b8246da1f9625e71e195335b58e44ad},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.24241. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Reproducibility of heart rate variability (HRV) analysis is limited by differences in preprocessing and computational conventions across software platforms. We developed HRV Studio, an open-source PyQt6-based desktop application integrating transparent HRV analysis with automated quality-control (QC) diagnostics. Validation included large-scale agreement with NeuroKit2, targeted Kubios benchmarking, spectral-method comparison, synthetic perturbation testing, recording-duration sensitivity analysis, and arrhythmia-focused QC stress testing. HRV Studio showed near-identical agreement for the widely used time-domain indices RMSSD and SDNN under matched conditions. In the primary five-minute NeuroKit2 comparison, frequency-domain median relative errors were 1.35% for LF, 0.18% for HF, and 1.41% for LF/HF, while VLF remained more convention-sensitive (37.79%). Nonlinear Poincaré indices also demonstrated high consistency. Sequence-harmonized Kubios benchmarking confirmed near-identical agreement for time-domain and nonlinear indices and strong agreement for most frequency-domain measures. Extended ten-minute analyses reproduced the same overall pattern with lower disagreement for some convention-sensitive spectral outputs. Synthetic and arrhythmia stress tests maintained 100% numerical stability while consistently triggering QC warnings. Overall, HRV Studio provides a transparent and reproducible platform for HRV research, with strong cross-platform consistency when NN sequences, preprocessing, and analytical conventions are harmonized. Stress-test results indicate computational robustness rather than clinical validation. Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-08-26 in cs.LG). Categorie arXiv: Medical Physics (physics.med-ph) ; Machine Learning (cs.LG); Software Engineering (cs.SE); Quantitative Methods (q-bio.QM). Pagina del lavoro: https://arxiv.org/abs/2608.24241 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-18T06:28:52.347Z dalla pagina https://arxiv.org/catchup/cs.LG/2026-08-26?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).