Metraipolis › archive › dc_ad2f2a3bf18e
CLC-YOLO: A Compact Channel-Gated Prototype Network for Real-Time Leakage-Aware Breast Ultrasound Lesion Segmentation — arXiv:2609.31702
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.31702
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-07T23:50:28.856Z
- SHA-256 of the archived text
e108e8c508dd6cb60c0a4340220bf7dbb6082f22cbc90ec7b60bb24581315c74- Stable URL of this page
https://metraipolis.com/documento/dc_ad2f2a3bf18e
How to cite
CLC-YOLO: A Compact Channel-Gated Prototype Network for Real-Time Leakage-Aware Breast Ultrasound Lesion Segmentation — arXiv:2609.31702 — arXiv (en), https://arxiv.org/abs/2609.31702 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_ad2f2a3bf18e (Metraipolis archive dc_ad2f2a3bf18e, sha256 e108e8c508dd6cb60c0a4340220bf7dbb6082f22cbc90ec7b60bb24581315c74)
BibTeX
@misc{dcad2f2a3bf18e,
title = {CLC-YOLO: A Compact Channel-Gated Prototype Network for Real-Time Leakage-Aware Breast Ultrasound Lesion Segmentation — arXiv:2609.31702},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.31702},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_ad2f2a3bf18e; sha256 e108e8c508dd6cb60c0a4340220bf7dbb6082f22cbc90ec7b60bb24581315c74},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.31702. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Reliable breast ultrasound lesion segmentation requires accurate boundaries and evaluation that prevents patients or duplicate images from crossing data splits. We propose Channel Local Contrast (CLC), a compact refinement of the YOLO26 segmentation prototype head. CLC adds a fixed local high-pass residual controlled by 64 zero-initialized, bounded channel gates. Baseline and CLC were compared in five matched folds on each of four breast ultrasound datasets. BUS-BRA used patient-disjoint outer tests with separate inner validation. BUS-UCLM and BrEaST used patient-grouped validation folds; BUSI used duplicate-component groups because patient identifiers are unavailable. Group-macro Dice increased by 1.68, 3.11, 1.12, and 2.45 percentage points on BUS-BRA, BUS-UCLM, BUSI, and BrEaST, respectively. Only the BUS-BRA paired 95% confidence interval excluded zero. CLC adds 64 parameters and 0.0049 giga floating-point operations (GFLOPs). At 640 pixels, single-T4, batch-one, 16-bit floating-point (FP16) TensorRT graph times were 2.1478 ms for CLC and 2.0512 ms for baseline, excluding preprocessing and postprocessing. CLC increased group-macro Dice across all four datasets with a measured T4 forward-pass overhead of 0.0966 ms. Code: this https URL Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-29 in cs.CV). Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV). Pagina del lavoro: https://arxiv.org/abs/2609.31702 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-07T23:29:26.881Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-09-29?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).