Metraipolis › archive › dc_ac9996e9ec17

Localized Thermal Management of Induction-Heated Microrobots for Hyperthermia Applications — arXiv:2610.09069

Source
arXiv (en)
Original
https://arxiv.org/abs/2610.09069
License (as archived)
CC0-1.0
Archived
2026-10-08T14:17:07.017Z
SHA-256 of the archived text
4dab2dbd1c584334dd8cb127f292717d889b91d5ecd915f92fc08fa4429d292e
Stable URL of this page
https://metraipolis.com/documento/dc_ac9996e9ec17

How to cite

Localized Thermal Management of Induction-Heated Microrobots for Hyperthermia Applications — arXiv:2610.09069 — arXiv (en), https://arxiv.org/abs/2610.09069 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_ac9996e9ec17 (Metraipolis archive dc_ac9996e9ec17, sha256 4dab2dbd1c584334dd8cb127f292717d889b91d5ecd915f92fc08fa4429d292e)
BibTeX
@misc{dcac9996e9ec17,
  title = {Localized Thermal Management of Induction-Heated Microrobots for Hyperthermia Applications — arXiv:2610.09069},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2610.09069},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_ac9996e9ec17; sha256 4dab2dbd1c584334dd8cb127f292717d889b91d5ecd915f92fc08fa4429d292e},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.09069. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Induction-heated microrobots face a fundamental thermal management challenge: the alternating magnetic fields required for localized hyperthermia simultaneously generate parasitic ohmic heating within the actuation coils. Conventional cooling approaches can fail because conductive cooling structures placed near the coil can couple to the time-varying field, generating additional electromagnetic losses. This paper addresses this architectural limitation by evaluating two liquid-cooling frameworks designed to isolate the electromagnetic workspace: an indirect configuration utilizing an external copper water block, and a direct architecture routing coolant internally through a hollow helical coil. Evaluated over a 100~s window with multi-point thermocouple telemetry, the indirect water-block configuration failed due to secondary inductive coupling with the block itself, acting as an unintended susceptor that drove the block temperature to an extreme peak of 805$^{\circ}$C. In contrast, the direct internal cooling architecture successfully extracted ohmic losses at the source, sustaining a localized ablation tip temperature of 63.4$^{\circ}$C while strictly restricting surrounding fluid and boundary surfaces below defined thresholds of 33.9$^{\circ}$C and 37.6$^{\circ}$C, respectively. These results establish coil-level fluidic integration as a key design principle for thermally isolated microrobot actuation and provide a hardware foundation for future spatially controlled hyperthermia.

Tema degli esploratori: calcolo e infrastrutture (elenco arXiv eess.SY, nuovi lavori del giorno).
Categorie arXiv: Systems and Control (eess.SY).
Pagina del lavoro: https://arxiv.org/abs/2610.09069 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-08T13:28:30.540Z dalla pagina https://arxiv.org/list/eess.SY/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).