Metraipolis › archive › dc_ac819837fb9d

Uncertainty-Guided Handshake: Efficient Human-in-the-Loop Refinement for Surgical-Grade Glioma Segmentation — arXiv:2610.01452

Source
arXiv (en)
Original
https://arxiv.org/abs/2610.01452
License (as archived)
CC0-1.0
Archived
2026-10-06T19:13:33.709Z
SHA-256 of the archived text
cb501723cfd354f6d0288412d44b2014c651c2b3e9f70ccadde06166e9a5ed76
Stable URL of this page
https://metraipolis.com/documento/dc_ac819837fb9d

How to cite

Uncertainty-Guided Handshake: Efficient Human-in-the-Loop Refinement for Surgical-Grade Glioma Segmentation — arXiv:2610.01452 — arXiv (en), https://arxiv.org/abs/2610.01452 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_ac819837fb9d (Metraipolis archive dc_ac819837fb9d, sha256 cb501723cfd354f6d0288412d44b2014c651c2b3e9f70ccadde06166e9a5ed76)
BibTeX
@misc{dcac819837fb9d,
  title = {Uncertainty-Guided Handshake: Efficient Human-in-the-Loop Refinement for Surgical-Grade Glioma Segmentation — arXiv:2610.01452},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2610.01452},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_ac819837fb9d; sha256 cb501723cfd354f6d0288412d44b2014c651c2b3e9f70ccadde06166e9a5ed76},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.01452. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

While state-of-the-art automated models for medical image segmentation achieve high mean performance, they frequently suffer from localized, catastrophic failures that preclude safe clinical deployment, particularly in neuro-oncology. Interactive segmentation frameworks mitigate this by incorporating human oversight, but traditionally impose prohibitive cognitive and temporal workloads by requiring clinicians to manually search for errors. In this project, we present an efficient, Hybrid Structural-Aleatoric Human-in-the-Loop framework for glioma segmentation that bridges the gap between automated baseline performance and surgical-grade precision, achieving sub-2.0 mm HD95 on curated benchmarks while providing safety-net routing for structural failures across real-world clinical data. By extracting voxel-wise Test-Time Augmentation (TTA) uncertainty and applying hierarchical topological filtering, our method proactively isolates high-risk structural anomalies. We comprehensively evaluated our approach on a challenging out-of-distribution clinical stress-test cohort (N = 362). Operating under a simulated Human Oracle, the framework improved the Whole Tumor (WT) Dice score from 0.891 to 0.914 and reduced the 95th percentile Hausdorff Distance (HD95) from 5.82 mm to 4.76 mm. Critically for surgical safety, the system rescued severe boundary failures in the Tumor Core, reducing mean HD95 from 17.96 mm to 14.83 mm (improving absolute TC Dice to 0.356). These spatial rescues were achieved while demanding a median interactive workload of just 11.3% of the target volume. Acknowledging this as a simulated upper bound lacking real-world cognitive friction, the framework nevertheless demonstrates a highly Pareto-efficient pathway for safely deploying clinical AI.

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-10-02 in cs.CV).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV).
Pagina del lavoro: https://arxiv.org/abs/2610.01452 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-06T17:37:36.789Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-10-02?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).