Metraipolis › archive › dc_ac76f1c73072
Per-Bundle, Pre-Reconstruction Inversion for Temporal CT: Flux-Compensation Design and Multi-Patient Generalization — arXiv:2610.19229
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2610.19229
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-15T15:04:02.458Z
- SHA-256 of the archived text
d9d2cf25e46b2dea4d0a9efe2408b8e62cd28aa1ac52d2cb5491d14d1069442a- Stable URL of this page
https://metraipolis.com/documento/dc_ac76f1c73072
How to cite
Per-Bundle, Pre-Reconstruction Inversion for Temporal CT: Flux-Compensation Design and Multi-Patient Generalization — arXiv:2610.19229 — arXiv (en), https://arxiv.org/abs/2610.19229 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_ac76f1c73072 (Metraipolis archive dc_ac76f1c73072, sha256 d9d2cf25e46b2dea4d0a9efe2408b8e62cd28aa1ac52d2cb5491d14d1069442a)
BibTeX
@misc{dcac76f1c73072,
title = {Per-Bundle, Pre-Reconstruction Inversion for Temporal CT: Flux-Compensation Design and Multi-Patient Generalization — arXiv:2610.19229},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2610.19229},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_ac76f1c73072; sha256 d9d2cf25e46b2dea4d0a9efe2408b8e62cd28aa1ac52d2cb5491d14d1069442a},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.19229. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Paper 1 established the per-bundle statistical limits of Temporal CT (TCT) and benchmarked a learned prior on a single patient at a uniform incident count $N_0$. This paper lifts both restrictions. SNN2, a Gauss-Newton estimator, converges to the per-bundle Poisson maximum-likelihood solution and is the prior-free baseline. N$_0$FC, a bow-tie and tube-current-modulation co-design, compresses within-bundle photon-flux dynamic range. V8c is a neural-network residual corrector trained on a 19-patient corpus stratified by water-equivalent diameter (WED). T2bp, a per-patient empirical-Bayes post-processor, combines per-bundle Poisson likelihoods with a prior built from the patient's own bundles; it requires no training, so it cannot inherit a mismatched training prior. Results use Paper 1's bias-charged Dose Inflation Factor (DIF), extended to per-ray budgets. V8c beats SNN2 on in-distribution patients under baseline acquisition but fails out of distribution. Composed with SNN2, T2bp matches or beats T2bp$\circ$V8c on three of four N$_0$FC test cells (WED 207-342 mm), with the largest gains on the high-WED and out-of-distribution patients, and trails by 3% on the fourth. On 23 non-test corpus volumes, N$_0$FC with closed-loop tube-current modulation lowers the per-volume median middle-path Cramer-Rao floor, as a DIF, from 23-48 under baseline acquisition to 3.3-6.3, near the equal-attenuation value 13/3; T2bp$\circ$SNN2 reaches this floor without training, its mean squared error 0.74-1.26 times the floor (median 0.89) over the bulk of each volume. Acquisition co-design removes most of the attenuation-contrast penalty, and a training-free estimator attains the resulting limit. The remaining three- to six-fold gap to dose parity with single-source CT, and the high-attenuation tail, are the target of inter-bundle priors in later work. Tema degli esploratori: statistica e scienza dei dati (elenco arXiv eess.IV, nuovi lavori del giorno). Categorie arXiv: Image and Video Processing (eess.IV). Pagina del lavoro: https://arxiv.org/abs/2610.19229 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-15T14:07:53.874Z dalla pagina https://arxiv.org/list/eess.IV/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).