Metraipolis › archive › dc_ac1ff30e4c9a

Dual-Faraday-laser-pumped cesium beam clock with $7.7\times 10^{-13}/\sqrtτ$ frequency stability — arXiv:2608.06169

Source
arXiv (en)
Original
https://arxiv.org/abs/2608.06169
License (as archived)
CC0-1.0
Archived
2026-10-31T10:54:03.547Z
SHA-256 of the archived text
ae5571225e34d830f8f828b3a0fa49b0c9965e6186c65415b1ed41b16d5f7459
Stable URL of this page
https://metraipolis.com/documento/dc_ac1ff30e4c9a

How to cite

Dual-Faraday-laser-pumped cesium beam clock with $7.7\times 10^{-13}/\sqrtτ$ frequency stability — arXiv:2608.06169 — arXiv (en), https://arxiv.org/abs/2608.06169 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_ac1ff30e4c9a (Metraipolis archive dc_ac1ff30e4c9a, sha256 ae5571225e34d830f8f828b3a0fa49b0c9965e6186c65415b1ed41b16d5f7459)
BibTeX
@misc{dcac1ff30e4c9a,
  title = {Dual-Faraday-laser-pumped cesium beam clock with $7.7times 10^-13/sqrtτ$ frequency stability — arXiv:2608.06169},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2608.06169},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_ac1ff30e4c9a; sha256 ae5571225e34d830f8f828b3a0fa49b0c9965e6186c65415b1ed41b16d5f7459},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.06169. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Compact cesium beam clocks are major frequency references for deployable timing systems. However, further improvement of their short-term frequency stability is limited by the clock signal-to-noise ratio (SNR). Although two-laser optical pumping can increase the effective atomic utilization, the achievable clock SNR has long been limited by laser-induced frequency-to-amplitude noise conversion. Here, we demonstrate a compact dual-Faraday-laser-pumped (DFP) Cs beam clock enabled by a low-frequency-noise atom-referenced laser architecture. The intracavity Faraday anomalous dispersion optical filter provides inherent alignment to the Cs D$_2$ resonances, while modulation transfer spectroscopy offers suppressed frequency noise and drift. The resulting laser system supports robust turnkey operation with a Lorentzian linewidth of 2.12 kHz. The DFP Cs clock achieves a clock SNR of 46,365 in a 1-Hz bandwidth and a fractional Allan deviation of $7.7\times 10^{-13}/\sqrt\tau$ , with Hadamard deviation reaching $7.7\times 10^{-15}$ at 10,000 s. This work pushes the fractional frequency stability of a compact Cs beam clock into the $10^{-13}/\sqrt\tau$ regime, providing a pathway toward high-performance Cs frequency references for field-deployable precision timing, navigation, and synchronization.

Tema degli esploratori: fisica e astronomia (retro-catalogo arXiv: annunci del 2026-08-07 in quant-ph).
Categorie arXiv: Atomic Physics (physics.atom-ph) ; Quantum Physics (quant-ph).
Pagina del lavoro: https://arxiv.org/abs/2608.06169 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-31T10:40:45.654Z dalla pagina https://arxiv.org/catchup/quant-ph/2026-08-07?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).