Metraipolis › archive › dc_aba69fa4ed3b
Single-shot coherent process tomography and mid-infrared polarimetry with undetected photons — arXiv:2609.31043
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.31043
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-08T03:46:34.156Z
- SHA-256 of the archived text
57116dd6b54b40a45bc97cd0bf8b30b97d68f72c7e0e4eea9171eced1d666b36- Stable URL of this page
https://metraipolis.com/documento/dc_aba69fa4ed3b
How to cite
Single-shot coherent process tomography and mid-infrared polarimetry with undetected photons — arXiv:2609.31043 — arXiv (en), https://arxiv.org/abs/2609.31043 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_aba69fa4ed3b (Metraipolis archive dc_aba69fa4ed3b, sha256 57116dd6b54b40a45bc97cd0bf8b30b97d68f72c7e0e4eea9171eced1d666b36)
BibTeX
@misc{dcaba69fa4ed3b,
title = {Single-shot coherent process tomography and mid-infrared polarimetry with undetected photons — arXiv:2609.31043},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.31043},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_aba69fa4ed3b; sha256 57116dd6b54b40a45bc97cd0bf8b30b97d68f72c7e0e4eea9171eced1d666b36},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.31043. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Measurements with undetected photons infer properties of a probe beam that is never detected, transferring mid-infrared information onto silicon-friendly wavelengths. Tomography in this paradigm has so far relied on switched settings or scanned phases, referenced across a drift-sensitive campaign; no protocol reads all Jones parameters from one frame. We show that a folded nonlinear interferometer with a diagonally pumped crossed-crystal source performs coherent process tomography of the undetected beam in a single spectrometer frame: it reconstructs all seven parameters of the beam's round-trip Jones matrix, the coherent part of the channel. Birefringent group-delay walk-off, normally a calibration nuisance, acts as a frequency multiplexer: each Jones-matrix element is assigned its own carrier, a spectral fringe period paired with a detector port. Because the multiplexing exploits the down-conversion bandwidth rather than merely tolerating it, a single Fourier transform per detector trace returns all four moduli and all three relative phases across that bandwidth, i.e., the full round-trip Jones spectrum up to a global phase, with no scan or setting change (after a one-time reference frame). Simultaneity makes every relative phase immune to common-mode drift, and a dark carrier, a self-interference term that unitarity forces to vanish, provides a built-in null test. For realistic parameters of a periodically poled KTP source the scheme yields wavelength-resolved mid-infrared polarimetry across 3.5-4.2 microns (~80 spectral points per Jones element) on a silicon camera, extending to depth-resolved Jones matrices, i.e., polarization-sensitive optical coherence tomography with undetected photons. A Fisher-information analysis, the first we are aware of in undetected-photon tomography, sets the precision budget and compares delay multiplexing to sequential protocols at equal photon number. Tema degli esploratori: fisica e astronomia (retro-catalogo arXiv: annunci del 2026-09-28 in quant-ph). Categorie arXiv: Quantum Physics (quant-ph) ; Optics (physics.optics). Pagina del lavoro: https://arxiv.org/abs/2609.31043 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-08T03:14:19.116Z dalla pagina https://arxiv.org/catchup/quant-ph/2026-09-28?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).