Pooled Saliva Specimens for SARS-CoV-2 Testing — Europe PMC PPR:PPR222209
- Source
- Europe PMC
- Original
- https://europepmc.org/article/PPR/PPR222209
- DOI
- 10.1101/2020.10.02.20204859
- License (as archived)
- CC0-1.0
- Archived
- 2026-11-07T09:08:05.828Z
- SHA-256 of the archived text
80c86a545e5c789936ea1c0d4a300e26b770780d430b1e6d40cff293d08ba838- Stable URL of this page
https://metraipolis.com/documento/dc_aab68a9fe7c2
How to cite
Pooled Saliva Specimens for SARS-CoV-2 Testing — Europe PMC PPR:PPR222209 — Europe PMC, https://europepmc.org/article/PPR/PPR222209 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_aab68a9fe7c2 (Metraipolis archive dc_aab68a9fe7c2, sha256 80c86a545e5c789936ea1c0d4a300e26b770780d430b1e6d40cff293d08ba838)
BibTeX
@misc{dcaab68a9fe7c2,
title = {Pooled Saliva Specimens for SARS-CoV-2 Testing — Europe PMC PPR:PPR222209},
howpublished = {Europe PMC},
url = {https://europepmc.org/article/PPR/PPR222209},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_aab68a9fe7c2; sha256 80c86a545e5c789936ea1c0d4a300e26b770780d430b1e6d40cff293d08ba838},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: Europe PMC, https://europepmc.org/article/PPR/PPR222209. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
We evaluated saliva (SAL) specimens for SARS-CoV-2 RT-PCR testing by comparison of 459 prospectively paired nasopharyngeal (NP) or mid-turbinate (MT) swabs from 449 individuals with the aim of using saliva for asymptomatic screening. Samples were collected in a drive-through car line for symptomatic individuals (N=380) and in the emergency department (ED) (N=69). The percent positive and negative agreement of saliva compared to nasopharyngeal swab were 81.1% (95% CI: 65.8% – 90.5%) and 99.8% (95% CI: 98.7% – 100%), respectively. The sensitivity increased to 90.0% (95% CI: 74.4% – 96.5%) when considering only samples with moderate to high viral load (Cycle threshold (Ct) for the NP <=34). Pools of five saliva specimens were also evaluated on three platforms: bioMérieux NucliSENS easyMAG with ABI 7500Fast (CDC assay), Hologic Panther Fusion, and Roche COBAS 6800. The median loss of signal upon pooling was 2-4 Ct values across the platforms. The sensitivity of detecting a positive specimen in a pool compared with testing individually was 100%, 93%, and 95% for CDC 2019-nCoV Real-Time RT-PCR, Panther Fusion® SARS-CoV-2 assay, and cobas® SARS-CoV-2 test respectively, with decreased sample detection trending with lower viral load. We conclude that although pooled saliva testing, as collected in this study, is not quite as sensitive as NP/MT testing, saliva testing is adequate to detect individuals with higher viral loads in an asymptomatic screening program, does not require swabs or viral transport media for collection, and may help to improve voluntary screening compliance for those individuals averse to various forms of nasal collections. Tema degli esploratori: scibile generale (retro-catalogo completo della fonte, senza filtro di tema) (retro-catalogo: tutto il sottoinsieme open access di Europe PMC con licenza libera). Pubblicazione: medRxiv, 2020 (prima pubblicazione 2020-10-05). Identificativi: DOI 10.1101/2020.10.02.20204859. Pagina: https://europepmc.org/article/PPR/PPR222209 — https://doi.org/10.1101/2020.10.02.20204859. Autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza dell'articolo dichiarata da Europe PMC: CC0 (la versione è indicata dall'editore sulla pagina). Abstract riportato senza modifiche al contenuto, con attribuzione; deposito marcato CC0. Letto il 2026-11-07T09:03:55.918Z tramite l'API REST ufficiale di Europe PMC (EMBL-EBI), nel rispetto del robots.txt e del crawl-delay.