Metraipolis › archive › dc_a9fb4322e918

Sharing a Fabric with Collective Communication: Two Storage Penalties in Deep Learning Training — arXiv:2609.06506

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.06506
License (as archived)
CC0-1.0
Archived
2026-10-16T13:07:11.367Z
SHA-256 of the archived text
33ae0040b3042fc28a1dec53312f5c050513c5245eef0eb9223723fd1f73b465
Stable URL of this page
https://metraipolis.com/documento/dc_a9fb4322e918

How to cite

Sharing a Fabric with Collective Communication: Two Storage Penalties in Deep Learning Training — arXiv:2609.06506 — arXiv (en), https://arxiv.org/abs/2609.06506 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_a9fb4322e918 (Metraipolis archive dc_a9fb4322e918, sha256 33ae0040b3042fc28a1dec53312f5c050513c5245eef0eb9223723fd1f73b465)
BibTeX
@misc{dca9fb4322e918,
  title = {Sharing a Fabric with Collective Communication: Two Storage Penalties in Deep Learning Training — arXiv:2609.06506},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.06506},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_a9fb4322e918; sha256 33ae0040b3042fc28a1dec53312f5c050513c5245eef0eb9223723fd1f73b465},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.06506. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Distributed DL training on HPC systems often shares one network fabric between NCCL/RCCL collective communication and parallel-filesystem I/O. Using a real GNN training workload on a Slingshot-11 system, we show that this sharing imposes two distinct costs. The primary cost is heavy-tailed DataLoader stalls: the typical DataLoader wait is just 15 ms at steady state, yet spikes to multiple seconds in 28% of Lustre iterations and 12% of VAST iterations. The secondary cost is traffic-class contention on collective communication: Lustre I/O stalls the all-reduce by up to 145$\times$ in an isolated benchmark. The two costs arise from different mechanisms. I/O stall latency affects any storage path that traverses the shared fabric, whereas all-reduce network contention occurs only when storage and collective communication share the same traffic class. Their common root cause is that storage I/O traverses the shared fabric. This work shows that node-local NVMe staging via DYAD (Our code is publicly available at this https URL ) eliminates both effects by keeping storage I/O off that path. Across a full training epoch, DYAD achieves a 7.4 times speedup over direct Lustre reads and a 1.06 times speedup over VAST. By the second epoch, once the local cache is fully warmed, DataLoader stalls are eliminated entirely, allowing DYAD to reach a 1.31 times speedup over VAST.

Tema degli esploratori: calcolo e infrastrutture (retro-catalogo arXiv: annunci del 2026-09-09 in cs.DC).
Categorie arXiv: Distributed, Parallel, and Cluster Computing (cs.DC) ; Performance (cs.PF).
Pagina del lavoro: https://arxiv.org/abs/2609.06506 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-16T13:02:21.559Z dalla pagina https://arxiv.org/catchup/cs.DC/2026-09-09?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).