Metraipolis › archive › dc_a9980592c978
FYC: FPR-Disparity Weight Perturbation and Youden Calibration for Fair Deepfake Detection — arXiv:2610.37882
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2610.37882
- License (as archived)
- CC0-1.0
- Archived
- 2026-11-01T02:40:14.988Z
- SHA-256 of the archived text
bdc7811b128c0fe3cadadcc5a8011275c92bbac336c66aa191f1a1d8637fb332- Stable URL of this page
https://metraipolis.com/documento/dc_a9980592c978
How to cite
FYC: FPR-Disparity Weight Perturbation and Youden Calibration for Fair Deepfake Detection — arXiv:2610.37882 — arXiv (en), https://arxiv.org/abs/2610.37882 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_a9980592c978 (Metraipolis archive dc_a9980592c978, sha256 bdc7811b128c0fe3cadadcc5a8011275c92bbac336c66aa191f1a1d8637fb332)
BibTeX
@misc{dca9980592c978,
title = {FYC: FPR-Disparity Weight Perturbation and Youden Calibration for Fair Deepfake Detection — arXiv:2610.37882},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2610.37882},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_a9980592c978; sha256 bdc7811b128c0fe3cadadcc5a8011275c92bbac336c66aa191f1a1d8637fb332},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.37882. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Deepfake detectors routinely achieve high aggregate accuracy while exhibiting substantial demographic disparities in their errors: false-positive rates differ by double digits across gender and skin tone. Most existing remedies require either full retraining with a fairness-aware objective or demographic-annotated training data, both impractical when only a pretrained checkpoint is available, while label-free post-hoc calibrators leave the detector's weights unchanged. We introduce FYC (FPR-disparity Weight Perturbation and Youden Calibration), a two-stage post-hoc method that perturbs a detector's weights under an FPR-disparity criterion, then calibrates a separate decision threshold for each demographic group - requiring no architectural changes and no full retraining. Evaluated against every detector benchmarked on AI-Face v2 across six intersectional gender x skin-tone groups, FYC outperforms the field on 18 of 21 reported fairness and utility metrics, including purpose-built fairness architectures, at a fraction of the training cost. We further identify why the choice of fairness criterion is critical: the original Demographic Parity objective used in prior weight-perturbation work is architecture-dependent and unpredictable, improving two of four evaluated architectures, leaving a third largely unchanged, and substantially degrading the fourth (PG-FDD), with no way to anticipate the outcome for a given checkpoint in advance. Conditioning the same objective on real images only - our FPR-disparity criterion - eliminates this unpredictability, improving fairness and accuracy jointly across all four architectures with no exceptions. Tema degli esploratori: statistica e scienza dei dati (elenco arXiv cs.CV, nuovi lavori del giorno). Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV). Pagina del lavoro: https://arxiv.org/abs/2610.37882 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-11-01T02:16:43.857Z dalla pagina https://arxiv.org/list/cs.CV/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).