Metraipolis › archive › dc_a91ed202594f

XPos3R: Cross-Modal Transformer for Intraoperative 2D/3D Registration — arXiv:2609.10733

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.10733
License (as archived)
CC0-1.0
Archived
2026-10-16T07:21:42.826Z
SHA-256 of the archived text
162601af948e0bf2bd2782319fbbe367b3156497322e87ec105517fe60156d03
Stable URL of this page
https://metraipolis.com/documento/dc_a91ed202594f

How to cite

XPos3R: Cross-Modal Transformer for Intraoperative 2D/3D Registration — arXiv:2609.10733 — arXiv (en), https://arxiv.org/abs/2609.10733 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_a91ed202594f (Metraipolis archive dc_a91ed202594f, sha256 162601af948e0bf2bd2782319fbbe367b3156497322e87ec105517fe60156d03)
BibTeX
@misc{dca91ed202594f,
  title = {XPos3R: Cross-Modal Transformer for Intraoperative 2D/3D Registration — arXiv:2609.10733},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.10733},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_a91ed202594f; sha256 162601af948e0bf2bd2782319fbbe367b3156497322e87ec105517fe60156d03},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.10733. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Intraoperative 2D/3D registration, which aligns live X-ray images with preoperative volumes, is essential for image-guided interventions. Previous regression-based methods suffer from limited generalization, thus requiring time-consuming patient-specific retraining. Inspired by recent geometry foundation models such as DUSt3R, we propose XPos3R, a generalizable pose regression method that eliminates preoperative preparation. Unlike existing geometry models designed for homogeneous inputs, XPos3R extends this paradigm to multi-modal inputs, namely 2D X-rays and 3D volumes. Specifically, we introduce an asymmetric encoder-decoder architecture that improves cross-modal feature alignment while maintaining computational efficiency. To scale training under limited medical data, we adopt an anatomy-specific data curation strategy and construct million-scale synthetic datasets. Evaluated on real-world benchmarks, a single pretrained XPos3R surpasses patient-specific methods in both accuracy and robustness. With test-time optimization completed in seconds, it further reduces the 3D error to <4 mm and the reprojection error to <1 mm. The strong generalization, accuracy, and efficiency of XPos3R highlight its clinical potential, while its asymmetric framework may inspire broader cross-modal vision geometry tasks.

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-11 in eess.IV).
Categorie arXiv: Image and Video Processing (eess.IV).
Pagina del lavoro: https://arxiv.org/abs/2609.10733 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-16T06:59:40.718Z dalla pagina https://arxiv.org/catchup/eess.IV/2026-09-11?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).