Metraipolis › archive › dc_a8bcfe277c28

Anatomy-Aware Dexterity-Driven Design Optimization of Surgical Continuum Robots — arXiv:2609.30745

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.30745
License (as archived)
CC0-1.0
Archived
2026-10-08T01:39:29.121Z
SHA-256 of the archived text
ad99fd5f63b4cb8d927c21212bdd5e3869a9f1e65859fb5dc4931c4de82990af
Stable URL of this page
https://metraipolis.com/documento/dc_a8bcfe277c28

How to cite

Anatomy-Aware Dexterity-Driven Design Optimization of Surgical Continuum Robots — arXiv:2609.30745 — arXiv (en), https://arxiv.org/abs/2609.30745 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_a8bcfe277c28 (Metraipolis archive dc_a8bcfe277c28, sha256 ad99fd5f63b4cb8d927c21212bdd5e3869a9f1e65859fb5dc4931c4de82990af)
BibTeX
@misc{dca8bcfe277c28,
  title = {Anatomy-Aware Dexterity-Driven Design Optimization of Surgical Continuum Robots — arXiv:2609.30745},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.30745},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_a8bcfe277c28; sha256 ad99fd5f63b4cb8d927c21212bdd5e3869a9f1e65859fb5dc4931c4de82990af},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.30745. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Performing complex medical procedures with continuum robots requires careful selection of their geometric design parameters. The robot should have high dexterity in the specific anatomical environment of its procedure. This work presents a design optimization method that considers both dexterity and anatomy. We introduce the Reachable Volumetric Dexterous Solid Angle (RVDSA) metric as our objective, which measures the ability of a robot's end effector to reach the points in a goal volume from different directions via collision-free paths from a start configuration. We present a computationally efficient motion planner to compute this objective function for a given robotic design, and we use an asymptotically optimal simulated annealing optimizer to compute an optimized design. We applied our new method to optimize the design of a bimanual dexterous sheaths robot for performing procedures on cancerous polyps in colon anatomies, achieving a 78% higher RVDSA on average than optimizing for 3D voxel coverage alone.

Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-28 in cs.AI).
Categorie arXiv: Robotics (cs.RO) ; Artificial Intelligence (cs.AI).
Pagina del lavoro: https://arxiv.org/abs/2609.30745 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-08T01:12:14.475Z dalla pagina https://arxiv.org/catchup/cs.AI/2026-09-28?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).