Metraipolis › archive › dc_a86ade62301b
Occlusal Geometry in Closed Form for Orthodontic Report Generation — arXiv:2609.13237
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.13237
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-15T23:16:38.074Z
- SHA-256 of the archived text
40ef1d19201d3abbf0076ccfaf79e72197f4d05515c7251bf705a486832182c5- Stable URL of this page
https://metraipolis.com/documento/dc_a86ade62301b
How to cite
Occlusal Geometry in Closed Form for Orthodontic Report Generation — arXiv:2609.13237 — arXiv (en), https://arxiv.org/abs/2609.13237 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_a86ade62301b (Metraipolis archive dc_a86ade62301b, sha256 40ef1d19201d3abbf0076ccfaf79e72197f4d05515c7251bf705a486832182c5)
BibTeX
@misc{dca86ade62301b,
title = {Occlusal Geometry in Closed Form for Orthodontic Report Generation — arXiv:2609.13237},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.13237},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_a86ade62301b; sha256 40ef1d19201d3abbf0076ccfaf79e72197f4d05515c7251bf705a486832182c5},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.13237. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Orthodontic report generation from intraoral data is normally cast as multimodal captioning, yet the released Bite2Text scan pairs are supplied already registered in occlusion, which makes several core occlusal quantities directly measurable rather than inferable. The system reported here exploits that property: an anatomical frame is recovered per case from arch taper and arch closure instead of the stated RAS convention, which does not hold across the release, and each arch is reduced to an occlusal ridge profile in arch-angle coordinates yielding overbite, overjet, midline deviation, transverse overlap, crossbite extent, cusp interdigitation lag, and the occlusal curves in closed form. Gradient boosting maps 31 such measurements onto 13 template fields, a field being predicted only where patient-level cross-validation beats its own majority baseline, and a deterministic renderer emits the corpus six-part narrative; a ConvNeXt-Tiny classifier over the five standardised photographic views is fused per field, raising mean field accuracy from 0.601 to 0.683. Reimplementation of the challenge evaluator shows that its BLEU-4 and METEOR are local variants whose F-mean weights recall nine to one, that two clinicians agree on 47 percent of findings for the same patient, and that a constant report consequently outscores a genuine second clinician report by 0.165 captioning. Held-out scores reach BLEU-4 0.458 and METEOR 0.677 against intraoral scan references and 0.278 and 0.507 against photograph references, and the submitted system placed third in the ODIN 2026 Bite2Text test phase at 0.2680 and 0.4629, within 0.022 BLEU-4 of first, running on CPU in under ten seconds per case. The dataset and code are available at this https URL Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-15 in cs.CL). Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV) ; Computation and Language (cs.CL). Pagina del lavoro: https://arxiv.org/abs/2609.13237 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-15T22:51:09.994Z dalla pagina https://arxiv.org/catchup/cs.CL/2026-09-15?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).