Metraipolis › archive › dc_a7f024e9e81e

A Unified Kinematic Representation Enables Reusable Biological Joint Moment Estimation — arXiv:2610.09150

Source
arXiv (en)
Original
https://arxiv.org/abs/2610.09150
License (as archived)
CC0-1.0
Archived
2026-10-08T12:48:50.465Z
SHA-256 of the archived text
024dc3ada1042a118b24f890ac1ba42d2fbbe257c26dc68e99140424a6975911
Stable URL of this page
https://metraipolis.com/documento/dc_a7f024e9e81e

How to cite

A Unified Kinematic Representation Enables Reusable Biological Joint Moment Estimation — arXiv:2610.09150 — arXiv (en), https://arxiv.org/abs/2610.09150 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_a7f024e9e81e (Metraipolis archive dc_a7f024e9e81e, sha256 024dc3ada1042a118b24f890ac1ba42d2fbbe257c26dc68e99140424a6975911)
BibTeX
@misc{dca7f024e9e81e,
  title = {A Unified Kinematic Representation Enables Reusable Biological Joint Moment Estimation — arXiv:2610.09150},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2610.09150},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_a7f024e9e81e; sha256 024dc3ada1042a118b24f890ac1ba42d2fbbe257c26dc68e99140424a6975911},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.09150. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Objective: Data-driven models that estimate physiological states, particularly biological joint moments, are widely used in exoskeleton control. However, these estimators are often coupled to device-specific sensor configurations, limiting controller transfer and the use of open-source biomechanics datasets. Methods: We proposed joint kinematics as an intermediate representation that decouples hardware-specific sensing from downstream biological joint moment estimation. A joint-moment estimator using joint angles and angular velocities was trained exclusively on open-source biomechanics data and evaluated using kinematics from a hip exoskeleton, knee exoskeleton, and inertial measurement unit (IMU) sensor suite during level-ground, ramp-ascent, and ramp-descent walking. Results: The estimator achieved an root mean square error (RMSE) of 0.17 Nm/kg and coefficient of determination (R2) of 0.79 using hip exoskeleton kinematics, 0.19 Nm/kg and 0.62 using knee exoskeleton kinematics, and 0.15 Nm/kg and 0.85 using kinematics derived from IMUs across bilateral hip, knee, and ankle joints. Conclusion: Joint kinematics enabled an estimator trained only on open-source data to operate across distinct wearable platforms. Significance: This framework may reduce target-device data collection and support transferable biological joint moment estimation for exoskeleton control and wearable biomechanics.

Tema degli esploratori: statistica e scienza dei dati (elenco arXiv cs.RO, nuovi lavori del giorno).
Categorie arXiv: Robotics (cs.RO).
Pagina del lavoro: https://arxiv.org/abs/2610.09150 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-08T12:18:30.490Z dalla pagina https://arxiv.org/list/cs.RO/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).