Metraipolis › archive › dc_a7ab79c1b53b

PLRS-IC: A Dual-Calibration Framework for Chest X-Ray Vision-Language Alignment — arXiv:2609.39266

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.39266
License (as archived)
CC0-1.0
Archived
2026-10-07T14:46:01.161Z
SHA-256 of the archived text
31e4cb5d89b8f55243edc886768066e5073b4b33396511b89ea46ba35be95d83
Stable URL of this page
https://metraipolis.com/documento/dc_a7ab79c1b53b

How to cite

PLRS-IC: A Dual-Calibration Framework for Chest X-Ray Vision-Language Alignment — arXiv:2609.39266 — arXiv (en), https://arxiv.org/abs/2609.39266 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_a7ab79c1b53b (Metraipolis archive dc_a7ab79c1b53b, sha256 31e4cb5d89b8f55243edc886768066e5073b4b33396511b89ea46ba35be95d83)
BibTeX
@misc{dca7ab79c1b53b,
  title = {PLRS-IC: A Dual-Calibration Framework for Chest X-Ray Vision-Language Alignment — arXiv:2609.39266},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.39266},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_a7ab79c1b53b; sha256 31e4cb5d89b8f55243edc886768066e5073b4b33396511b89ea46ba35be95d83},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.39266. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Fine-grained vision-language alignment in chest radiography enables zero-shot classification, grounding, and segmentation without task-specific annotations. However, this alignment is fundamentally hindered by two intertwined sources of ambiguity: projection-induced visual mismatch and patient-agnostic semantic overlap. First, at the local feature level, frontal and lateral radiographs exhibit distinct appearances for the same clinical finding, rendering a shared patch-text similarity geometry inherently suboptimal. Compounding this visual ambiguity is a semantic mismatch during global contrastive optimization, where instance-level objectives penalize cross-patient pairs as strict negatives even when they share identical positive clinical concepts. To address this dual ambiguity, we propose PLRS-IC, a unified dual-calibration framework for chest X-ray representation learning. At the local alignment stage, Projection-Conditioned Low-Rank Residual Similarity (PLRS) dynamically adapts patch-text matching to projection-specific manifolds using a bounded, parameter-efficient low-rank residual. At the global optimization stage, Information-Content-Calibrated Soft False-Negative Suppression (IC-SFNS) leverages a corpus-derived information-theoretic prior to soften the penalty of semantically overlapping negatives without altering original contrastive assignments. Extensive experiments across nine public zero-shot benchmark settings demonstrate that our framework yields consistent improvements in classification, grounding, and segmentation, validating the necessity of dual-calibration in medical vision-language pre-training.

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-10-01 in cs.CV).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV).
Pagina del lavoro: https://arxiv.org/abs/2609.39266 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-07T14:19:00.716Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-10-01?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).