Metraipolis › archive › dc_a782a3265d89
LightMIS: Ultra-Lightweight Medical Image Segmentation Without a Stage-Wise Decoder — arXiv:2609.28327
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.28327
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-08T12:35:21.843Z
- SHA-256 of the archived text
0e13046a53f7bcbb7dd7e9d4d9ef8de38840fb694630a1477b79e182ce241773- Stable URL of this page
https://metraipolis.com/documento/dc_a782a3265d89
How to cite
LightMIS: Ultra-Lightweight Medical Image Segmentation Without a Stage-Wise Decoder — arXiv:2609.28327 — arXiv (en), https://arxiv.org/abs/2609.28327 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_a782a3265d89 (Metraipolis archive dc_a782a3265d89, sha256 0e13046a53f7bcbb7dd7e9d4d9ef8de38840fb694630a1477b79e182ce241773)
BibTeX
@misc{dca782a3265d89,
title = {LightMIS: Ultra-Lightweight Medical Image Segmentation Without a Stage-Wise Decoder — arXiv:2609.28327},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.28327},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_a782a3265d89; sha256 0e13046a53f7bcbb7dd7e9d4d9ef8de38840fb694630a1477b79e182ce241773},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.28327. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
We present LightMIS, a scalable family of ultra-lightweight convolutional networks for 2D binary medical image segmentation without a learned stage-wise decoder. LightMIS aligns the outputs of a five-level encoder to a common resolution using Scale-Aligned Projection blocks, aggregates them once, and refines the fused representation with an Adaptive Fusion Cascade. The cascade combines Adaptive Kernel Fusion with the proposed Progressive Receptive Fusion module, which uses temporary channel expansion, complementary depthwise receptive fields, and progressive cross-branch information transfer. We evaluate LightMIS-T, LightMIS-S, and LightMIS using five-fold cross-validation under a common nnU-Net v2.3.1 protocol on DRIVE, Kvasir-SEG, DSB18, BUSI, ISIC-2017, and ISIC-2018. Full LightMIS contains 0.131 M parameters and requires 0.575 GFLOPs for a $3\times256\times256$ input, achieving modality-macro Dice and IoU scores of 86.71% and 78.99%, respectively. Mobile U-ViT obtains 86.75% Dice and 79.07% IoU, so the observed differences are 0.04 and 0.08 percentage points. Relative to Mobile U-ViT, nnWNet, and nnU-Net, LightMIS reduces parameter count by 90.58$-$99.61% and GFLOPs by 82.54$-$96.14%. On an Arm Mali-G52 MC2 GPU, all LightMIS variants achieve full GPU delegation, with median delegated latency ranging from 53.31 ms for LightMIS-T to 138.31 ms for LightMIS. These results demonstrate a favorable accuracy-complexity trade-off and on-device execution feasibility for the evaluated tasks. The code is publicly available at this https URL . Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-24 in cs.CV). Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV). Pagina del lavoro: https://arxiv.org/abs/2609.28327 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-08T12:12:35.803Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-09-24?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).