Metraipolis › archive › dc_a74a5493584c
Attenuated total reflectance — Wikipedia (en)
- Source
- Wikipedia (en)
- Original
- https://en.wikipedia.org/wiki/Attenuated_total_reflectance
- License (as archived)
- CC-BY-SA-4.0
- Archived
- 2026-11-10T07:54:21.429Z
- SHA-256 of the archived text
ee373de628e4825ef5178d4af06bc2190ebeb39767709aad4896f117e8aee130- Stable URL of this page
https://metraipolis.com/documento/dc_a74a5493584c
How to cite
Attenuated total reflectance — Wikipedia (en) — Wikipedia (en), https://en.wikipedia.org/wiki/Attenuated_total_reflectance (CC-BY-SA-4.0); archived copy: https://metraipolis.com/documento/dc_a74a5493584c (Metraipolis archive dc_a74a5493584c, sha256 ee373de628e4825ef5178d4af06bc2190ebeb39767709aad4896f117e8aee130)
BibTeX
@misc{dca74a5493584c,
title = {Attenuated total reflectance — Wikipedia (en)},
howpublished = {Wikipedia (en)},
url = {https://en.wikipedia.org/wiki/Attenuated_total_reflectance},
note = {License CC-BY-SA-4.0; archived copy https://metraipolis.com/documento/dc_a74a5493584c; sha256 ee373de628e4825ef5178d4af06bc2190ebeb39767709aad4896f117e8aee130},
year = {2026}
}Archived text
Reproduced under CC-BY-SA-4.0. Attribution: Wikipedia (en), https://en.wikipedia.org/wiki/Attenuated_total_reflectance. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Attenuated total reflection (ATR) is a sampling technique used in conjunction with infrared spectroscopy which enables samples to be examined directly in the solid or liquid state without further preparation. ATR uses a property of total internal reflection resulting in an evanescent wave. A beam of infrared light (IR) is passed through the ATR crystal in such a way that it reflects at least once off the internal surface in contact with the sample. This reflection forms the evanescent wave which extends into the sample. The penetration depth into the sample is typically between 0.5 and 2 micrometres, with the exact value determined by the wavelength of light, the angle of incidence and the indices of refraction for the ATR crystal and the medium being probed. The number of reflections may be varied by varying the angle of incidence. The beam is then collected by a detector as it exits the crystal. Most modern infrared spectrometers can be converted to characterise samples via ATR by mounting the ATR accessory in the spectrometer's sample compartment. The accessibility, rapid sample turnaround and ease of use of ATR with Fourier transform infrared spectroscopy (FTIR) has led to substantial use by the scientific community. This evanescent effect only works if the crystal is made of an optical material with a higher refractive index than the sample being studied. Otherwise light is lost to the sample. In the case of a liquid sample, pouring a shallow amount over the surface of the crystal is sufficient. In the case of a solid sample, samples are firmly clamped to ensure good contact is made and to remove trapped air that would reduce signal intensity. The signal to noise ratio obtained depends on the number of reflections but also on the total length of the optical light path which dampens the intensity. Therefore, a general claim that more reflections give better sensitivity cannot be made. Typical materials for ATR crystals include germanium, KRS-5 and zinc selenide, while silicon is ideal for use in the far-IR region of the electromagnetic spectrum. The excellent mechanical properties of diamond make it an ideal material for ATR, particularly when studying very hard solids, although the broad diamond phonon band between 2600 and 1900 cm−1 significantly decreases signal to noise in this region. The shape of the crystal depends on the type of spectrometer and nature of the sample. With dispersive spectrometers, the crystal is a rectangular slab with chamfered edges, seen in cross-section in the illustrations. Other geometries use prisms, half-spheres, or thin sheets. Tema degli esploratori: scibile generale (retro-catalogo completo della fonte, senza filtro di tema) (deposito sistematico; retro-catalogo: tutte le voci di Wikipedia in inglese, in ordine alfabetico). Fonte: Wikipedia in inglese, voce «Attenuated total reflectance» — https://en.wikipedia.org/wiki/Attenuated_total_reflectance Wikidata Q300035: «technique used in conjunction with infrared spectroscopy enabling samples to be examined directly in the solid or liquid state without further preparation» (dati Wikidata in CC0 1.0) — https://www.wikidata.org/wiki/Q300035 Autori: i contributori di Wikipedia (cronologia: https://en.wikipedia.org/wiki/Attenuated_total_reflectance?action=history). Licenza: Creative Commons Attribuzione-Condividi allo stesso modo 4.0 (CC BY-SA 4.0) — https://creativecommons.org/licenses/by-sa/4.0/. Il riuso richiede attribuzione e stessa licenza. Estratto dell'introduzione non modificato nel contenuto; revisione 1379835747, consultata il 2026-11-10T07:50:25.615Z tramite l'API ufficiale di Wikipedia. Impronta SHA-256 dell'estratto: 6218e39a53ea0a037623bd9c587dd6f88eeb22222753fb55a034e11e547d4b9b