Metraipolis › archive › dc_a69270d0a627

Seeing Through the Glare: A Multi-Source Benchmark and Ocular-Adaptive Pixel MeanFlow for Eyeglass Reflection Removal — arXiv:2610.10703

Source
arXiv (en)
Original
https://arxiv.org/abs/2610.10703
License (as archived)
CC0-1.0
Archived
2026-10-09T06:30:09.025Z
SHA-256 of the archived text
e08612b2cd5dcda85fff90b620400005903dca109dc4a14e35f2f0e8f10269db
Stable URL of this page
https://metraipolis.com/documento/dc_a69270d0a627

How to cite

Seeing Through the Glare: A Multi-Source Benchmark and Ocular-Adaptive Pixel MeanFlow for Eyeglass Reflection Removal — arXiv:2610.10703 — arXiv (en), https://arxiv.org/abs/2610.10703 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_a69270d0a627 (Metraipolis archive dc_a69270d0a627, sha256 e08612b2cd5dcda85fff90b620400005903dca109dc4a14e35f2f0e8f10269db)
BibTeX
@misc{dca69270d0a627,
  title = {Seeing Through the Glare: A Multi-Source Benchmark and Ocular-Adaptive Pixel MeanFlow for Eyeglass Reflection Removal — arXiv:2610.10703},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2610.10703},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_a69270d0a627; sha256 e08612b2cd5dcda85fff90b620400005903dca109dc4a14e35f2f0e8f10269db},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.10703. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Eyeglass reflection removal is important across smartphone imaging, video conferencing, and other face-centric visual applications. The task is challenging because reflections range from mild photometric contamination to severe ocular occlusion, requiring selective correction and plausible reconstruction without altering identity or natural appearance. Existing datasets cover limited reflection conditions, constraining generalization to complex real-world scenes and systematic evaluation. We introduce \textbf{OcuBench}, a multi-source benchmark comprising 10,280 controllable synthetic pairs, 732 real-input pseudo-pairs, and 458 independent real-world test images, supporting both paired evaluation and assessment beyond generated supervision. We further propose \textbf{OcuFlow}, an ocular-adaptive pixel MeanFlow (pMF) framework for efficient, detail-preserving restoration. It combines geometry-adaptive representation with one-step pMF to focus reconstruction on reflection-obscured ocular regions, together with native-resolution frequency-preserving synthesis to retain reliable observed details. Experiments across diverse reflection conditions demonstrate that OcuFlow achieves consistent advantages in reflection removal quality, ocular fidelity, and efficiency. In a blind user study, it receives $67.32\%$ of selections, $6.2\times$ the next-best share. Both the code and dataset will be released.

Tema degli esploratori: statistica e scienza dei dati (elenco arXiv cs.CV, nuovi lavori del giorno).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV).
Pagina del lavoro: https://arxiv.org/abs/2610.10703 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-09T05:55:06.986Z dalla pagina https://arxiv.org/list/cs.CV/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).