Neural implants and human safety: single-fault detection for DC-coupled recording front ends — arXiv:2608.10361 — arXiv (en), https://arxiv.org/abs/2608.10361 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_a68ae069306f (Metraipolis archive dc_a68ae069306f, sha256 1e1c3af11eae1a4d29086623d1a99854e2a0ece290f60653ae1c894620f994c9)
BibTeX
@misc{dca68ae069306f,
title = {Neural implants and human safety: single-fault detection for DC-coupled recording front ends — arXiv:2608.10361},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2608.10361},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_a68ae069306f; sha256 1e1c3af11eae1a4d29086623d1a99854e2a0ece290f60653ae1c894620f994c9},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.10361. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
DC-coupled analogue front ends (AFEs) for neural implants provide a low-area solution. However, removing the coupling capacitor eliminates the intrinsic barrier that protects cortical tissue: a single-fault event, such as gate-oxide breakdown of a low-noise amplifier (LNA) input transistor, can open a direct DC path from the supply rail into the brain. On the stimulation side this hazard is well understood, and single-fault tolerance is enforced by a series DC-blocking capacitor; on the recording side, DC-coupled front ends discard the equivalent safeguard, yet their protection has gone almost unexamined. This paper presents a single-fault detection mechanism that monitors the LNA for the DC imbalance produced by such a failure and disables the amplifier before the resulting fault current can irreversibly damage tissue. The imbalance is encoded in the duty cycle of a current-starved relaxation oscillator and read out as a time-to-digital measurement. Designed in 65 nm, the mechanism resolves a worst-case fault of 6.4 nA across all corners within 0.81 ms - compliant with the ISO~14708-3 limit for an 8533 um2 electrode - opening a broader discussion of safety in DC-coupled recording. Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-08-12 in cs.HC). Categorie arXiv: Signal Processing (eess.SP) ; Human-Computer Interaction (cs.HC). Pagina del lavoro: https://arxiv.org/abs/2608.10361 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-19T06:11:23.455Z dalla pagina https://arxiv.org/catchup/cs.HC/2026-08-12?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).