Metraipolis › archive › dc_a67c1125a9a4

Task-Relevant Feature-Dynamics Fidelity Enables Zero-Shot Sim-to-Real Transfer for Robotic Ultrasound Scanning — arXiv:2608.29516

Source
arXiv (en)
Original
https://arxiv.org/abs/2608.29516
License (as archived)
CC0-1.0
Archived
2026-10-17T10:06:48.038Z
SHA-256 of the archived text
8d02df41724025e1fc8da2e7a69013a61ebc0f7cbbf2513daacfe093bc3d7e93
Stable URL of this page
https://metraipolis.com/documento/dc_a67c1125a9a4

How to cite

Task-Relevant Feature-Dynamics Fidelity Enables Zero-Shot Sim-to-Real Transfer for Robotic Ultrasound Scanning — arXiv:2608.29516 — arXiv (en), https://arxiv.org/abs/2608.29516 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_a67c1125a9a4 (Metraipolis archive dc_a67c1125a9a4, sha256 8d02df41724025e1fc8da2e7a69013a61ebc0f7cbbf2513daacfe093bc3d7e93)
BibTeX
@misc{dca67c1125a9a4,
  title = {Task-Relevant Feature-Dynamics Fidelity Enables Zero-Shot Sim-to-Real Transfer for Robotic Ultrasound Scanning — arXiv:2608.29516},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2608.29516},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_a67c1125a9a4; sha256 8d02df41724025e1fc8da2e7a69013a61ebc0f7cbbf2513daacfe093bc3d7e93},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.29516. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Robotic ultrasound policies operating directly on B-mode images require extensive interaction data, whereas real-robot data collection is costly and safety-constrained. Simulation provides a scalable alternative, but zero-shot transfer depends not only on single-frame realism but also on whether simulated observations reproduce task-relevant feature changes induced by probe motion. We term this cross-domain consistency task-relevant feature-dynamics fidelity (TR-FDF). Under local regularity assumptions, our contraction analysis shows that greater sensitivity of TR-FDF mismatch to probe motion reduces the effective closed-loop contraction margin, whereas motion-independent errors primarily enlarge the residual error bound. Guided by this analysis, we develop a TR-FDF-oriented ultrasound simulator that combines a shared structural intermediate domain, trajectory-level fixed noise, and few-step conditional flow generation. In phantom experiments, a policy trained exclusively in simulation succeeded in 390 of 400 zero-shot deployments across four target planes. The simulator achieved an FID of 29.66 and generated observations at 67.1 Hz. Controlled interventions, ablations, and baseline comparisons showed that TR-FDF sensitivity complements single-frame realism in predicting zero-shot transfer performance.

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-01 in cs.RO).
Categorie arXiv: Robotics (cs.RO).
Pagina del lavoro: https://arxiv.org/abs/2608.29516 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-17T09:58:57.780Z dalla pagina https://arxiv.org/catchup/cs.RO/2026-09-01?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).