Metraipolis › archive › dc_a5a42d7749a2
Error Detection for PET/CT Radiology Reports: Domain-Specific vs Large Language Models — arXiv:2608.30021
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2608.30021
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-17T07:52:21.580Z
- SHA-256 of the archived text
162e09ba78e363378667b09f9bb63b329153946fa9c3502e08e52e57a98439c2- Stable URL of this page
https://metraipolis.com/documento/dc_a5a42d7749a2
How to cite
Error Detection for PET/CT Radiology Reports: Domain-Specific vs Large Language Models — arXiv:2608.30021 — arXiv (en), https://arxiv.org/abs/2608.30021 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_a5a42d7749a2 (Metraipolis archive dc_a5a42d7749a2, sha256 162e09ba78e363378667b09f9bb63b329153946fa9c3502e08e52e57a98439c2)
BibTeX
@misc{dca5a42d7749a2,
title = {Error Detection for PET/CT Radiology Reports: Domain-Specific vs Large Language Models — arXiv:2608.30021},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2608.30021},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_a5a42d7749a2; sha256 162e09ba78e363378667b09f9bb63b329153946fa9c3502e08e52e57a98439c2},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.30021. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Errors in radiology reports can adversely affect patient treatment, yet automated report quality assurance remains challenging because errors are often subtle and require domain expertise to detect. Although large language models (LLMs) have recently been proposed for radiology report verification, their ability to detect clinically meaningful errors beyond chest X-ray datasets remains under-explored. To this end, we present the first systematic evaluation of language models for PET/CT report error detection, comparing compact domain-specific models with SOTA open-weight LLMs. We collected 30,633 oncology FDG PET/CT reports from 23 radiologists over 10 years. We trained domain-specific BERT models to detect clinically motivated synthetic reporting errors and evaluated alongside zero-/few-shot Qwen3-32B, Gemma-3-27B and Llama-3.3-70B on a held-out benchmark of 11,500 reports. A 15M-parameter model achieved 94.4% balanced accuracy with a 5.8% false-positive rate, compared with 84.0% for the strongest prompted LLM. Task-specific adaptation of Llama-3.3-70B closed this performance gap (94.4%) but retained substantially greater computational requirements. Our results suggest that domain-specific training matters more than model scale for PET/CT report error detection, supporting compact models as an accurate and computationally efficient approach to automated radiology report quality assurance. Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-01 in cs.AI). Categorie arXiv: Machine Learning (cs.LG) ; Artificial Intelligence (cs.AI). Pagina del lavoro: https://arxiv.org/abs/2608.30021 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-17T07:28:26.816Z dalla pagina https://arxiv.org/catchup/cs.AI/2026-09-01?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).