Metraipolis › archive › dc_a4d97ee724ce

Quantum-Limited Optical Vector Analysis — arXiv:2509.25950

Source
arXiv (en)
Original
https://arxiv.org/abs/2509.25950
License (as archived)
CC0-1.0
Archived
2026-10-07T15:22:45.004Z
SHA-256 of the archived text
6e8c3c137e90415f423c6ec08366ddffc1f85da3cdc3a5c5436f324ca3faaeba
Stable URL of this page
https://metraipolis.com/documento/dc_a4d97ee724ce

How to cite

Quantum-Limited Optical Vector Analysis — arXiv:2509.25950 — arXiv (en), https://arxiv.org/abs/2509.25950 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_a4d97ee724ce (Metraipolis archive dc_a4d97ee724ce, sha256 6e8c3c137e90415f423c6ec08366ddffc1f85da3cdc3a5c5436f324ca3faaeba)
BibTeX
@misc{dca4d97ee724ce,
  title = {Quantum-Limited Optical Vector Analysis — arXiv:2509.25950},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2509.25950},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_a4d97ee724ce; sha256 6e8c3c137e90415f423c6ec08366ddffc1f85da3cdc3a5c5436f324ca3faaeba},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2509.25950. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Optical Vector Analysers (OVA) are critical for emerging technologies such as integrated photonics and optical positioning. Achieving a sensitivity near the Standard Quantum Limit (SQL) while acquiring a wide spectrum allows an accurate measurement of targets that are fragile, non-linear, or that scatter most of the probe light away. Existing OVAs operate with a sensitivity orders of magnitude below the SQL. In this paper, we use a free-running interferometer with a frequency range of 20 THz as an OVA. We introduce novel methods to mitigate the phase noise and obtain a unit signal-to-noise ratio for powers at the fW level. We apply this technique towards quantifying the fabrication quality of microring resonators in thin-film Lithium Niobate. Our characterisation yields a signal-to-noise ratio above 1 with much less than 1 circulating photon and reveals a quality factor above 5 millions, unambiguously attributed to low internal losses.

Tema degli esploratori: fisica e astronomia (retro-catalogo arXiv: annunci del 2026-10-01 in quant-ph).
Categorie arXiv: Optics (physics.optics) ; Quantum Physics (quant-ph).
Pagina del lavoro: https://arxiv.org/abs/2509.25950 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-07T14:53:56.908Z dalla pagina https://arxiv.org/catchup/quant-ph/2026-10-01?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).