Metraipolis › archive › dc_a33f331581e7
A comparison of performance metrics for cloth face masks as source control devices for simulated cough and exhalation aerosols — Europe PMC PPR:PPR285712
- Source
- Europe PMC
- Original
- https://europepmc.org/article/PPR/PPR285712
- DOI
- 10.1101/2021.02.16.21251850
- License (as archived)
- CC0-1.0
- Archived
- 2026-11-05T20:59:33.111Z
- SHA-256 of the archived text
d3e2c8bcf7b54e7ae2b63964503b13a29aebcb698e9409b9a2f44309aba5d7a2- Stable URL of this page
https://metraipolis.com/documento/dc_a33f331581e7
How to cite
A comparison of performance metrics for cloth face masks as source control devices for simulated cough and exhalation aerosols — Europe PMC PPR:PPR285712 — Europe PMC, https://europepmc.org/article/PPR/PPR285712 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_a33f331581e7 (Metraipolis archive dc_a33f331581e7, sha256 d3e2c8bcf7b54e7ae2b63964503b13a29aebcb698e9409b9a2f44309aba5d7a2)
BibTeX
@misc{dca33f331581e7,
title = {A comparison of performance metrics for cloth face masks as source control devices for simulated cough and exhalation aerosols — Europe PMC PPR:PPR285712},
howpublished = {Europe PMC},
url = {https://europepmc.org/article/PPR/PPR285712},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_a33f331581e7; sha256 d3e2c8bcf7b54e7ae2b63964503b13a29aebcb698e9409b9a2f44309aba5d7a2},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: Europe PMC, https://europepmc.org/article/PPR/PPR285712. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Universal mask wearing is recommended by the Centers for Disease Control and Prevention to help control the spread of COVID-19. Masks reduce the expulsion of respiratory aerosols (called source control) and offer some protection to the wearer. However, masks vary greatly in their designs and construction materials, and it is not clear which are most effective. Our study tested 15 reusable cloth masks (which included face masks, neck gaiters, and bandanas), two medical masks, and two N95 filtering facepiece respirators as source control devices for aerosols ≤ 7 µm produced during simulated coughing and exhalation. These measurements were compared with the mask filtration efficiencies, airflow resistances, and fit factors. The source control collection efficiencies for the cloth masks ranged from 17% to 71% for coughing and 35% to 66% for exhalation. The filtration efficiencies of the cloth masks ranged from 1.4% to 98%, while the fit factors were 1.3 to 7.4 on an elastomeric manikin headform and 1.0 to 4.0 on human test subjects. The correlation coefficients between the source control efficacies and the other performance metrics ranged from 0.31 to 0.66 and were significant in all but one case. However, none of the alternative metrics were strong predictors of the source control performance of cloth masks. Our results suggest that a better understanding of the relationships between source control performance and metrics like filtration efficiency, airflow resistance, and fit factor are needed to develop simple methods to estimate the effectiveness of masks as source control devices for respiratory aerosols. Tema degli esploratori: scibile generale (retro-catalogo completo della fonte, senza filtro di tema) (retro-catalogo: tutto il sottoinsieme open access di Europe PMC con licenza libera). Pubblicazione: medRxiv, 2021 (prima pubblicazione 2021-02-19). Identificativi: DOI 10.1101/2021.02.16.21251850. Pagina: https://europepmc.org/article/PPR/PPR285712 — https://doi.org/10.1101/2021.02.16.21251850. Autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza dell'articolo dichiarata da Europe PMC: CC0 (la versione è indicata dall'editore sulla pagina). Abstract riportato senza modifiche al contenuto, con attribuzione; deposito marcato CC0. Letto il 2026-11-05T20:48:23.114Z tramite l'API REST ufficiale di Europe PMC (EMBL-EBI), nel rispetto del robots.txt e del crawl-delay.